Enzymes electroactive

Ion Transport Stability Adhesion Multienzyme and Multilayer Configurations Immobilization of Redox Mediators Derivatization of Monomers before Conducting Polymer Electrosynthesis Direct Electrical Modulation of Enzymes Electroactive Polymer Hydrogels... [Pg.456]

Many compounds of biomedical interest, both of endogenous and exogenous origin, are heterocyclic in structure. Many of these compounds are electroactive at potentials useful for LCEC analysis. Methods for the determination of both ascorbic acid and uric acid were developed in the early days of LCEC. The important enzyme... [Pg.25]

Monitoring enzyme catalyzed reactions by voltammetry and amperometry is an extremely active area of bioelectrochemical interest. Whereas liquid chromatography provides selectivity, the use of enzymes to generate electroactive products provides specificity to electroanalytical techniques. In essence, enzymes are used as a derivatiz-ing agent to convert a nonelectroactive species into an electroactive species. Alternatively, electrochemistry has been used as a sensitive method to follow enzymatic reactions and to determine enzyme activity. Enzyme-linked immunoassays with electrochemical detection have been reported to provide even greater specificity and sensitivity than other enzyme linked electrochemical techniques. [Pg.28]

A wide variety of enzymes have been used in conjunction with electrochemical techniques. The only requirement is that an electroactive product is formed during the reaction, either from the substrate or as a cofactor (i.e. NADH). In most cases, the electroactive products detected have been oxygen, hydrogen peroxide, NADH, or ferri/ferrocyanide. Some workers have used the dye intermediates used in classical colorimetric methods because these dyes are typically also electroactive. Although an electroactive product must be formed, it does not necessarily have to arise directly from the enzyme reaction of interest. Several cases of coupling enzyme reactions to produce an electroactive product have been described. The ability to use several coupled enzyme reactions extends the possible use of electrochemical techniques to essentially any enzyme system. [Pg.28]

The simplest method of coupling enzymatic reactions to electrochemical detection is to monitor an off-line reaction using FIAEC or LCEC. The enzymatic reaction is carried out in a test tube under controlled conditions with aliquots being taken at timed intervals. These aliquots are then analyzed for the electroactive product and the enzyme activity in the sample calculated from the generated kinetic information. [Pg.29]

Another approach to improve selectivity is to use an enzyme electrode. The enzyme ascorbate oxidase has been used successfully to remove ascorbate as an interference of in vivo voltammetric electrodes 219,320) Ascorbate oxidase converts the ascorbic acid to dehydroascorbate which is not electroactive in the potential region used for in vivo analysis. [Pg.38]

For application of protein-immobilized porous materials to sensor fields, use of an electroactive substance as the framework material is important. DeLouise and Miller demonstrated the immobilization of glutathione-S-transferase in electrochemically etched porous silicon films [134], which are attractive materials for the construction of biosensors and may also have utility for the production of immobilized enzyme bioreactors. Not limited to this case, practical applications of nanohybrids from biomolecules and mesoporous materials have been paid much attention. Examples of the application of such hybrids are summarized in a later section of this chapter. [Pg.124]

In amperometry, the current produced by the oxidation or reduction of an electroactive analyte species at an electrode surface is monitored under controlled potential conditions. The magnitude of the current is then related to the quantity of analyte present. However, as both antibody and antigen are not intrinsically electroactive, a suitable label must be introduced to the immunocomplex to promote an electrochemical reaction at the immunosensors. In this respect, enzyme labels including the... [Pg.154]


See other pages where Enzymes electroactive is mentioned: [Pg.1493]    [Pg.287]    [Pg.1493]    [Pg.287]    [Pg.1940]    [Pg.103]    [Pg.115]    [Pg.173]    [Pg.176]    [Pg.177]    [Pg.184]    [Pg.185]    [Pg.427]    [Pg.73]    [Pg.75]    [Pg.33]    [Pg.69]    [Pg.598]    [Pg.601]    [Pg.604]    [Pg.618]    [Pg.629]    [Pg.363]    [Pg.60]    [Pg.68]    [Pg.81]    [Pg.85]    [Pg.141]    [Pg.143]    [Pg.155]    [Pg.157]    [Pg.266]    [Pg.268]    [Pg.379]    [Pg.380]    [Pg.469]    [Pg.490]    [Pg.504]    [Pg.534]    [Pg.536]    [Pg.559]    [Pg.564]    [Pg.568]    [Pg.141]    [Pg.217]   