Energy focusing devices

Electrostatic analyser (ESA) An energy-focusing device used in a double-focusing mass spectrometer to increase mass specnal resolution. [Pg.305]

Chapter 3 Reflectrons and Other Energy-Focusing Devices... [Pg.48]

Electrostatic analyzer. A velocity-focusing device for producing an electrostatic field perpendicular to the direction of ion travel (usually used in combination with a magnetic analyzer for mass analysis). The effect is to bring to a common focus all ions of a given kinetic energy. [Pg.429]

The subject of the study can be either a single energy-using device, such as a pump, or an entire ventilation system with all its components. A study focuses on the life cycle of the system or device, and normally is a comparison of two or more alternatives. The goal is to find the most economical solution on the basis of the total costs (investment and operation). [Pg.1373]

Figure 16.6—Linear time of flight (TOF) and principle of the reflectron. 1) Sample and sample holder 2) MALDI ionisation device 3 and 3 ) extraction and acceleration grid (5 000 V potential drop) 4) control grid 5) multichannel collector plate 6) electron multiplier 7) signal output. The bottom figure shows a reflectron, which is essentially an electrostatic mirror that is used to time-focus ions of the same mass, but which have different initial energies. This device increases resolution, which can attain several thousand. Figure 16.6—Linear time of flight (TOF) and principle of the reflectron. 1) Sample and sample holder 2) MALDI ionisation device 3 and 3 ) extraction and acceleration grid (5 000 V potential drop) 4) control grid 5) multichannel collector plate 6) electron multiplier 7) signal output. The bottom figure shows a reflectron, which is essentially an electrostatic mirror that is used to time-focus ions of the same mass, but which have different initial energies. This device increases resolution, which can attain several thousand.
In general, traditional electrode materials are substituted by electrode superstructures designed to facilitate a specific task. Thus, various modifiers have been attached to the electrode that lower the overall activation energy of the electron transfer for specific species, increase or decrease the mass transport, or selectively accumulate the analyte. These approaches are the key issues in the design of chemical selectivity of amperometric sensors. The long-term chemical and functional stability of the electrode, although important for chemical sensors as well, is typically focused on the use of modified electrodes in energy conversion devices. Examples of electroactive modifiers are shown in Table 7.2. [Pg.216]


See other pages where Energy focusing devices is mentioned: [Pg.177]    [Pg.66]    [Pg.108]    [Pg.50]    [Pg.177]    [Pg.72]    [Pg.242]    [Pg.20]    [Pg.47]    [Pg.48]    [Pg.177]    [Pg.66]    [Pg.108]    [Pg.50]    [Pg.177]    [Pg.72]    [Pg.242]    [Pg.20]    [Pg.47]    [Pg.48]    [Pg.1310]    [Pg.180]    [Pg.563]    [Pg.35]    [Pg.892]    [Pg.892]    [Pg.61]    [Pg.22]    [Pg.306]    [Pg.488]    [Pg.351]    [Pg.201]    [Pg.420]    [Pg.131]    [Pg.65]    [Pg.450]    [Pg.146]    [Pg.470]    [Pg.163]    [Pg.98]    [Pg.131]    [Pg.183]   


SEARCH



Energy focusing electrostatic devices

Focusing device

Reflectrons and Other Energy-Focusing Devices

© 2024 chempedia.info