Levitation electromagnetic

Fig. 8.5. Schematic of electromagnetic levitator with CO2 laser heating system... Fig. 8.5. Schematic of electromagnetic levitator with CO2 laser heating system...
Electromagnetic bearing Electromagnetically levitated spindle Magnetic spindle... [Pg.815]

Holland-Moritz D, Schenk T, Convert P, Hansen T, Herlach DM (2005) Electromagnetic levitation apparatus for diffraction investigations on the short-range order of undercooled metallic melts. Meas Sd Technol 16(2) 372—380... [Pg.98]

Kobatake H, Khosroabadi H, Fukuyama H (2012) Normal spectral emissivity measurement of liquid iron and nickel using electromagnetic levitation in direct current magnetic Field. Metall Mater Trans A 43(7) 2466-2472... [Pg.98]

Kawamura et al. ]50] successfully measured the normal spectral emissivity over a wavelength range between 550 and 1600 nm using an electromagnetic levitation technique, which assures measurements for molten silicon in undercooled conditions from 1553 to 1797 K, as shown in Fig. 4.13. [Pg.113]

The total hemispherical emissivity was measured using electromagnetic levitation by observing a relaxation time %i of the cooling curve due to radiation of molten silicon with a heat capacity of Cg, as shown in Fig. 4.11 and Eqs. (4.8)-(4.10) [51],... [Pg.114]

Application of noncontact AC calorimetry using electromagnetic levitation under a strong DC magnetic field enables direct measurement of thermal conductivity melt fiow is suppressed and heat transfer is controlled only by conduction within a droplet, so that a droplet behaves as if it were solid [35, 36]. Furthermore, measurements are free from the sensor insulation coating. The thermal conductivity can be obtained from the ( )-co relation simultaneously with total hemispherical emissivity st, as described in Section 4.3. [Pg.117]

M. Watanabe, Y. Katayama, and K. Kuribayashi, 2005, Precise measurement of density and stmcture of undercooled molten silicon by using synchrotron radiation combined with electromagnetic levitation technique ,... [Pg.131]

M. Watanabe, H. Kobatake, and H. Fukuyama, Precise density measurement for electromagnetically levitated liquid combined with the surface oscillation analysis , Int. J. Thermophys. in press. [Pg.132]

T. Tsukada, H. Fukuyama, and H. Kobatake, 2007, Determination of thermal conductivity and emissivity of electromagnetically levitated high-temperature droplet based on the periodic laser-heating method Theory , Int. J. Heat Mass Trans. 50, 3054-3061. [Pg.132]

T. Tsukada, K. Sugioka, H. Fukuyama, and H. Kohatake, 2007, Effect of static magnetic field on convection in electromagnetically levitated droplet of molten silicon , private communication. [Pg.132]

M. Przyborowski, T. Hibiya, M. Eguchi, and I. Egry, 1995, Surface tension measurement of molten silicon by the oscillating drop method using electromagnetic levitation , J. Cryst. Growth 151,... [Pg.134]

H. Fujii, T. Matsumoto, N. Hata, T. Nakano, M. Kohno, K. Nogi, Surface tension of molten silicon measured by the electromagnetic levitation method under microgravity. Metall. Mater. Trans. A-Phys. Metall. Mater. Sci. 31(6), 1585-1589 (2000)... [Pg.502]

Her] Cooling under electromagnetic levitation Solidification, microstmcture... [Pg.507]


See other pages where Levitation electromagnetic is mentioned: [Pg.313]    [Pg.79]    [Pg.13]    [Pg.1636]    [Pg.1639]    [Pg.324]    [Pg.446]    [Pg.231]    [Pg.233]    [Pg.601]    [Pg.601]    [Pg.290]    [Pg.472]    [Pg.234]    [Pg.91]    [Pg.109]    [Pg.109]    [Pg.109]    [Pg.110]    [Pg.117]    [Pg.124]    [Pg.126]    [Pg.129]    [Pg.130]    [Pg.221]    [Pg.29]   