Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

ECG-synchronization

For ECG-synchronized examinations of the cardio-thoracic anatomy, either ECG-triggered axial scanning or ECG-gated spiral scanning can be used. A technical overview on ECG-controlled CT scanning can be found in Flohr et al. (2003b). [Pg.15]

Direct current cardioversion is the process of administering a synchronized electrical shock to the chest. The purpose of DCC is to simultaneously depolarize all of the myocardial cells, resulting in interruption and termination of the multiple reentrant circuits and restoration of normal sinus rhythm. The initial energy level of the shock is 100 joules (J) if the DCC attempt is unsuccessful, successive cardioversion attempts maybe made at 200,300, and 360 J.14 Delivery of the shock is synchronized to the ECG by the cardioverter machine, such that the electrical charge is not delivered during... [Pg.117]

Recent studies demonstrate that cardiac resynchronization therapy (CRT) offers a promising approach to selected patients with chronic heart failure. Delayed electrical activation of the left ventricle, characterized on the ECG by a QRS duration that exceeds 120 ms, occurs in approximately one-third of patients with moderate to severe systolic heart failure. Since the left and right ventricles normally activate simultaneously, this delay results in asynchronous contraction of the left and right ventricles, which contributes to the hemodynamic abnormalities of this disorder. Implantation of a speciahzed biventricular pacemaker to restore synchronous activation of the ventricles can improve ventricular contraction and hemodynamics. Recent trials show improvements in exercise capacity, NYHA classification, quality of life, hemodynamic function, and hospitalizations. A device that combined CRT with an implantable cardioverter-defibrillator (ICD) improved survival in addition to functional status. CRT is currently indicated only in NYHA class ni-IV patients receiving optimal medical therapy (ACE inhibitors, diuretics, -blockers, and digoxin) and... [Pg.232]

Another technique for phase synchronization is the prospective ECG triggering or step-and-shoot mode technique. This technique is widely used for the quantification of the coronary calcium burden (calcium scor-... [Pg.195]


See other pages where ECG-synchronization is mentioned: [Pg.423]    [Pg.63]    [Pg.195]    [Pg.234]    [Pg.234]    [Pg.234]    [Pg.423]    [Pg.63]    [Pg.195]    [Pg.234]    [Pg.234]    [Pg.234]    [Pg.88]    [Pg.254]    [Pg.450]    [Pg.941]    [Pg.83]    [Pg.225]    [Pg.558]    [Pg.193]    [Pg.195]    [Pg.300]    [Pg.89]    [Pg.90]    [Pg.1023]    [Pg.204]    [Pg.218]    [Pg.613]    [Pg.536]    [Pg.554]    [Pg.1006]   
See also in sourсe #XX -- [ Pg.234 ]




SEARCH



Synchroner

Synchronicity

Synchronizing

Synchronous

© 2024 chempedia.info