Ductless Fume Hoods

The first fume hoods were simply boxes that were open on one side and connected to an exhaust duct. Since they were first introduced, many variations on this basic design have been made. Six of the major variants in fume hood airflow design are listed below with their characteristics. Conventional hoods are the most common and include benchtop, distillation, and walk-in hoods of the constant air volume (CAV), variable air volume (VAV), bypass and non-bypass variety, with or without airfoils. Auxihary air hoods and ductless fume hoods are not considered "conventional" and are used less often. Laboratory workers should know what kind of hood they are using and what its advantages and limitations are. [Pg.183]

Ductless fume hoods are ventilated enclosures that have their own fan, which draws air out of the hood and through filters and ultimately recirculates it into the laboratory. The filters are designed to trap vapors generated in the hood and exhaust "clean" air back into the laboratory. These hoods usually employ activated carbon filta-s. The collection efficiency of the filters decreases o er time. Ductless fume hoods have extremely limited applications and should be used only where the hazard is very low, where the access to the hood and the chemicals used in the hood are carefully controlled, and under the supervision of a laboratory supervisor who is familiar with the serious limitations and potentially hazardous characteristics of these devices. If these limitations cannot be accommodated, then this type of device should not be used. [Pg.186]

Most of the chemical fume hoods considered here consist of a cabinet or enclosure set at waist level (above a table or storage cabinet) that is connected to a blower located above the hood or external to the hood through a duct system. The cabinet has an open side (or sides) to 2illow a user to perform work within. A movable transparent sash separates the user from the work. Most chemical fume hoods have a sill that functions as an airfoil at the work surface below the sash. The connection to the blower might be by use of a v-belt, or it may be direct drive. This allows provision of a smooth flow of air with minimal turbulence. In some installations, axially mounted blowers are used, especially if multiple hoods are ducted into a common blower. Baffles located in the rear of the cabinet provide control of the air flow patterns, and can usually be adjusted to provide the best air flow around the experiment or procedure being performed. Many chemical fume hoods are equipped with air flow indicators, low flow monitors and alarms, and differenti2d pressure sensors to allow the user to operate safely. The major types of chemical fume hoods include the standard/conventional, W2dk-in, bypass, variable air volume, auxiliary air, or ductless types. Additional types include snorkels and canopies that are portable. Each type must be understood to be operated most efficiently within specifications (see the section below on safe operation). [Pg.2528]

Related at least in principle to ductless hoods are laminar flow hoods, sometimes called dean hoods. These are devices intended to protect the work being performed from particulates in the air, which is accomplished by bathing the work area with HEPA filtered air either blown at low velocity over the work area or blown from the bottom of the hood as an air curtain. Only approximately 10 % of the air flow is through the face of the hood. These are intended to protect the work or samples inside the hood, not primarily the user. These units should not be used in place of chemical fume hoods, rather they are used to protect the work from dust or pollen. [Pg.2528]

Ductless hoods are equipped with built-in fans and filter systems which trap the volatiles being removed. In this manner, the spent air can be returned to the laboratory, thereby eliminating the need for exhaust ducts. The filter system must be tailored to the types of fumes to be removed. Its use is therefore limited and... [Pg.84]