Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Digital implants

Figure 3. Whole mount of a chicken wing showing the skeletal pattern following implantation of a bead soaked in retinoic acid to the anterior margin. The digit pattern is duplicated 4 3 2 2 3 4. Figure 3. Whole mount of a chicken wing showing the skeletal pattern following implantation of a bead soaked in retinoic acid to the anterior margin. The digit pattern is duplicated 4 3 2 2 3 4.
Dillier et al., 1993] Dillier, N, Frolich, T., Kompis, M., Bogli, H., and Lai, W. (1993). Digital signal processing (DSP) applications for multiband loudness correction digital hearing aids and cochlear implants. J. Rehab. Res. andDevel., 30 95-109. [Pg.256]

In most people s jargon, biochips are not confined to microfluidics. Among many other roles, microfludics adapted from MicroLab technology can be extended for implants to deliver neurotransmitters or inhibitors in Parkinsonism, depression, schizophrenia, and so on, in a targeted and still microfluidic way without need for clumsy and not-so-effective oral administration. Nonetheless, when it comes to the brain, the original electronic and digital capabilities of the products of the computer chip industry are as much in the forefront of the news as their microfluidic potential, to say the least. [Pg.483]

The medical ID idea is the basis for a potential implantable on-a-chip record. On digital... [Pg.547]

Digital ICs are being manufactured in volume today (primarily by ion implantation) by companies like Vitesse for use in a variety of high speed applications and may be used in advanced high speed computing systems. [Pg.253]

Figure 4.2 Estimation of diffusion coefficients by autoradiography of tissue sections, (a) Digitized autoradiographic image of radiolabeled NGF released from a polymeric implant in a rat brain, reproduced from [18]. (b) The resulting concentration profile, obtained by scanning intensities from the autoradiographic image, and using calibrated standards to determine the local concentration the solid line indicates Equation 3-58. Figure 4.2 Estimation of diffusion coefficients by autoradiography of tissue sections, (a) Digitized autoradiographic image of radiolabeled NGF released from a polymeric implant in a rat brain, reproduced from [18]. (b) The resulting concentration profile, obtained by scanning intensities from the autoradiographic image, and using calibrated standards to determine the local concentration the solid line indicates Equation 3-58.
Fig. 12 Praziquantel particles and implants (a) SEM image of praziquantel particles (b) outward appearance of the fabricated implants, taken by digital camera (c) SEM image of the rqjresentative surface of the implants and (d) SEM image of the representative cross-section of the implants [180]... Fig. 12 Praziquantel particles and implants (a) SEM image of praziquantel particles (b) outward appearance of the fabricated implants, taken by digital camera (c) SEM image of the rqjresentative surface of the implants and (d) SEM image of the representative cross-section of the implants [180]...
The 3D melt-plotting is a computer-aided technique used for the fabrication of patient-specific implants or scaffolds endowed with a porous stracture which allows cell infiltration and vascularisation. The object to print can be designed by software or it is retrieved from a diagnostic examination such as X-ray or computer tomography. A computer-aided design software models and decomposes the object into two 2D slides. Thus, the digital information is sent to a robotic device (ie, Bioscaffolder) which builds up the object layer by layer (Seyednejad et al., 2011). PCL is one of the most used... [Pg.86]

Implantable devices are now capable of accumulating information on patient-device interaction. This is stored digitally and accessible via the programmer. Most devices report on the percentage of paced versus sensed events by chamber. This can be further subdivided by rate range. An example of one such display is shown in Fig. 2.15. [Pg.68]


See other pages where Digital implants is mentioned: [Pg.484]    [Pg.484]    [Pg.321]    [Pg.491]    [Pg.105]    [Pg.419]    [Pg.301]    [Pg.71]    [Pg.186]    [Pg.217]    [Pg.438]    [Pg.675]    [Pg.288]    [Pg.2654]    [Pg.317]    [Pg.189]    [Pg.222]    [Pg.393]    [Pg.485]    [Pg.51]    [Pg.562]    [Pg.198]    [Pg.53]    [Pg.451]    [Pg.53]    [Pg.206]    [Pg.268]    [Pg.57]    [Pg.502]    [Pg.1119]    [Pg.157]    [Pg.248]    [Pg.679]    [Pg.233]    [Pg.299]    [Pg.17]    [Pg.84]    [Pg.164]    [Pg.771]    [Pg.566]    [Pg.340]    [Pg.608]   
See also in sourсe #XX -- [ Pg.484 ]




SEARCH



© 2024 chempedia.info