Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Diagnostic records

Operational and maintenance plans should be prepared for the computer system and its associated measurement and control instrumentation. Operational plan review will focus on system reliability, performance, diagnostic records, instrument and system I/O calibration, and the provision of critical data to support the batch record. Procedures for controlling the system (e.g., system management, security, and process operations) should be reviewed to verify that they are current, in place, and being followed. For each procedure required for the system there should be documented evidence that the relevant operatives have been trained in its use. All procedures must be written and approved according to the site procedures for writing and approving SOPs. [Pg.632]

Clinical and diagnostic records. Clinical and diagnostic test records can have an important impact on public health policy and planning. [Pg.69]

Driver Machine Interface Diagnostic Recording Unit European Rail Traffic Management System... [Pg.2178]

A testing and diagnostic recording facility may be needed to prove that shutdown or isolation valves are functioning... [Pg.259]

The results of over 1 year of continuous, on-line acoustic emission (AE) structural surveillance of high temperature / high pressure steam headers, gained on 2 M-scale 600MW supercritical multifuel ENEL power units in normal operation, are presented in the paper. The influence of background noise, the correlation between plant operating conditions (steady load, load variations, startup / shutdown transients) and AE activity and the diagnostic evaluation of recorded AE events are also discussed. [Pg.75]

For each tube, the analyst carefully examines the complete eddy current record. Any indication above the detection threshold that did not lead to a confirmed computer diagnostic is manually examined. [Pg.1023]

Figure 3.10 shows the secondary ion spectra recorded from within the defect and its surroundings. The spectrum from the defective area clearly shows the presence of a polluting perfluorinated polyether structure (the C Fy peaks and the peak at mass 47 amu (CFO" ) are diagnostic of the polyether structure). [Pg.98]

It is not necessary to calibrate all test and measuring equipment. Some equipment may be used solely as an indicator, such as a thermometer, a clock, or a tachometer other equipment may be used for diagnostic purposes, to indicate if a fault exists. If such devices are not used for determining the acceptability of products and services or process parameters, their calibration is not essential. However, you should identify such devices as for Indication Purposes Only if their use for measurement is possible. You don t need to identify all clocks and thermometers fixed to walls unless they are used for measurement. Having observed that you record the time when observations were made, a zealous assessor may suggest that the clock be calibrated. If the time is not critical to product or process acceptability, calibration is unnecessary. [Pg.403]

A thorough physical examination and laboratory and diagnostic tests are performed before a child is accepted into a growth program. Before therapy is started, the nurse takes and records the patient s vital signs, height, and weight. [Pg.515]

Devices specifically intended for recording of X-ray diagnostic images are in Class lla. [Pg.176]

Fig. 18-11 Records of atmospheric CO2 in Antarctica for the past 1000 years. Open circles are ice-core data from Law Dome, on the coast of east Antarctica (Etheridge et al., 1996). Plus signs are direct measurements of CO2 in air samples collected monthly at the South Pole (NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, Colorado). Fig. 18-11 Records of atmospheric CO2 in Antarctica for the past 1000 years. Open circles are ice-core data from Law Dome, on the coast of east Antarctica (Etheridge et al., 1996). Plus signs are direct measurements of CO2 in air samples collected monthly at the South Pole (NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, Colorado).
Fig. 18-17 Ice core records of N2O. (a) Data of Machida et al. (1995) from the H15 ice core, east Antarctica, for the time period 1750-1950, and monthly atmospheric N2O measurements at the South Pole from the NOAA Climate and Diagnostics Laboratory, Boulder, CO, for the period 1989-1998. (b) Data from Leuenberger and Siegenthaler (1992) from the Byrd ice core in West Antarctica. Fig. 18-17 Ice core records of N2O. (a) Data of Machida et al. (1995) from the H15 ice core, east Antarctica, for the time period 1750-1950, and monthly atmospheric N2O measurements at the South Pole from the NOAA Climate and Diagnostics Laboratory, Boulder, CO, for the period 1989-1998. (b) Data from Leuenberger and Siegenthaler (1992) from the Byrd ice core in West Antarctica.
The frequencies of absorption bands present gives diagnostic information on the nature of functional groups in materials as well as information from any observed frequency shifts on aspects such as hydrogen bonding and crystallinity. In many cases, spectra can be recorded non-destructively using either reflection or transmission procedures. IR spectra of small samples can also be obtained through microscopes (IR microspectrometry). Chalmers and Dent [8] discuss the theory and practice of IR spectroscopy in their book on industrial analysis with vibrational spectroscopy. Standard spectra of additives for polymeric materials include the major collection by Hummel and Scholl [9]. [Pg.568]


See other pages where Diagnostic records is mentioned: [Pg.33]    [Pg.183]    [Pg.76]    [Pg.76]    [Pg.181]    [Pg.37]    [Pg.38]    [Pg.33]    [Pg.183]    [Pg.76]    [Pg.76]    [Pg.181]    [Pg.37]    [Pg.38]    [Pg.541]    [Pg.509]    [Pg.429]    [Pg.52]    [Pg.116]    [Pg.111]    [Pg.530]    [Pg.71]    [Pg.727]    [Pg.362]    [Pg.512]    [Pg.517]    [Pg.141]    [Pg.129]    [Pg.767]    [Pg.38]    [Pg.974]    [Pg.153]    [Pg.353]    [Pg.353]    [Pg.459]    [Pg.405]    [Pg.83]    [Pg.5]    [Pg.568]    [Pg.79]    [Pg.31]    [Pg.842]    [Pg.119]   
See also in sourсe #XX -- [ Pg.69 ]




SEARCH



© 2024 chempedia.info