Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Design and coordination

In this chapter, we tackle the integration design and coordination of a multisite refinery network. The main feature of the chapter is the development of a simultaneous analysis strategy for process network integration through a mixed-integer linear program (MILP). The performance of the proposed model in this chapter is tested on several industrial-scale examples to illustrate the economic potential and trade-offs involved in the optimization of the network. [Pg.55]

That a carefully designed and coordinated process such as air traffic control can suffer such problems with coordinating multiple controller process models (and procedures) attests to the difficulty of this design problem and the necessity for careful design and analysis. [Pg.295]

To fulfill the task of cooling lubrication safely, all elements of the cooling lubrication system, i.e., cooling lubricant, circulation system with feeding and cleaning devices, must be effectively designed and coordinated. [Pg.320]

ERP system specialist Participated in the negotiation and finalization process of the system interface design, and coordinated with R D engineer to develop interface for the ERP system. [Pg.222]

Session design and coordination At the start of the test, check if the participants fuUy understand the terms. Each session evaluation of 3-15 products. Sequential monadic evaluation of the products. With several evaluations, possible to evaluate until 60 products... [Pg.350]

Quality products shall be attained by robust accreditation systems, assessment procedures, curriculum design, and coordination between regulatory bodies like AICTE, UGC, MHRD, State Council for Higher Education (SCHE), NAAC, and NBA in the system. [Pg.605]

This study has pointed to the immense amount of design and coordination required to produce even the simplest self-rephcator. This means that, at least from the origin of biological life, the Earth has had amazingly intricate machines. As the explanation of the material closure requirement shows, the environment for life to exist must contain suitable materials in a suitable state for use. As the discussion of the... [Pg.218]

Frequency dependence is very significant when an accurate transient simulation on a distributed-parameter line, such as an overhead line and an underground cable, is to be carried out from the viewpoint of insulation design and coordination in a power system. However, a simulation can be carried out neglecting frequency dependence if a safer-side result is required because simulation with frequency dependence, in general, results in a lower overvoltage than that neglecting frequency dependence. [Pg.88]

The tower-footing impedance is always represented as a resistance as in Table 2.4 recommended by guides on insulation design and coordination of transmission lines and substations [26]. However, it is not pure resistance, but shows an inductive or a capacitive nature (see Figure 2.40) as investigated by many authors [10,15,23,31]. [Pg.231]

The results have indicated that the direct strike to a PW with 30 kA produces an overvoltage at a substation comparable to that in the BFO case with Iq = 100 kA. This fact should be carefully investigated, because this has not been considered in the standard insulation design and coordination of a substation. [Pg.260]


See other pages where Design and coordination is mentioned: [Pg.56]    [Pg.56]    [Pg.18]    [Pg.145]    [Pg.1000]    [Pg.510]    [Pg.158]    [Pg.677]    [Pg.145]    [Pg.159]    [Pg.184]    [Pg.224]    [Pg.253]    [Pg.431]    [Pg.122]    [Pg.123]    [Pg.184]    [Pg.209]    [Pg.413]    [Pg.37]   
See also in sourсe #XX -- [ Pg.239 , Pg.585 ]




SEARCH



© 2024 chempedia.info