Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Constituent-based evaluation

The biomonitoring communication database (Chapter 6) should be used to identify good evaluation criteria and feed into development of the standard default criteria and measures recommended above. For example, research could contrast goal- vs process-based evaluation criteria, or theory-, investigator-, and constituent-derived criteria, in terms of their ease of elicitation or use or utility in reliably predicting successful commu-... [Pg.134]

Chapter 8 Safety Evaluation of Essential Oils Constituent-Based Approach Utilized... [Pg.1119]

J Safety Evaluation of Essential Oils A Constituent-Based Approach... [Pg.185]

Classical ion trajectory computer simulations based on the BCA are a series of evaluations of two-body collisions. The parameters involved in each collision are tire type of atoms of the projectile and the target atom, the kinetic energy of the projectile and the impact parameter. The general procedure for implementation of such computer simulations is as follows. All of the parameters involved in tlie calculation are defined the surface structure in tenns of the types of the constituent atoms, their positions in the surface and their themial vibration amplitude the projectile in tenns of the type of ion to be used, the incident beam direction and the initial kinetic energy the detector in tenns of the position, size and detection efficiency the type of potential fiinctions for possible collision pairs. [Pg.1811]

In their fundamental paper on curve resolution of two-component systems, Lawton and Sylvestre [7] studied a data matrix of spectra recorded during the elution of two constituents. One can decide either to estimate the pure spectra (and derive from them the concentration profiles) or the pure elution profiles (and derive from them the spectra) by factor analysis. Curve resolution, as developed by Lawton and Sylvestre, is based on the evaluation of the scores in the PC-space. Because the scores of the spectra in the PC-space defined by the wavelengths have a clearer structure (e.g. a line or a curve) than the scores of the elution profiles in the PC-space defined by the elution times, curve resolution usually estimates pure spectra. Thereafter, the pure elution profiles are estimated from the estimated pure spectra. Because no information on the specific order of the spectra is used, curve resolution is also applicable when the sequence of the spectra is not in a specific order. [Pg.260]

Today, analytical evaluation is done on a large scale in a computerized way by means of data bases and expert systems (Sect. 8.3.6). In particular, a library search is a useful tool to identify pure compounds, confirm them and characterize constituents in mixtures. Additionally, unknown new substances may be classified by similarity analysis (Zupan [1986], Hippe [1991], Warr [1993], Hobert [1995]). The library search has its main application in such fields where a large number of components has to be related with large sets of data such as environmental and toxicological analysis (Scott [1995], Pellizarri et al. [1985]). [Pg.63]

Selection of on-site analytical techniques involves evaluation of many factors including the specific objectives of this work. Numerous instrumental techniques, GC, GC-MS, GC-MS-TEA, HPLC, HPLC-MS-MS, IR, FTIR, Raman, GC-FTIR, NMR, IMS, HPLC-UV-IMS, TOF, IC, CE, etc., have been employed for their laboratory-based determination. Most, however, do not meet on-site analysis criteria, (i.e., are not transportable or truly field portable, are incapable of analyzing the entire suite of analytes, cannot detect multiple analytes compounded with environmental constituents, or have low selectivity and sensitivity). Therefore, there exists no single technique that can detect all the compounds and there are only a few techniques exist that can be fielded. The most favored, portable, hand-held instrumental technique is ion mobility spectrometry (IMS), but limitations in that only a small subset of compounds, the inherent difficulty with numerous false positives (e.g., diesel fumes, etc.), and the length of time it takes to clear the IMS back to background are just two of its many drawbacks. [Pg.126]

Cefic claims that polymeric materials, reaction intermediates and substances used for R D should not be subject to the REACH evaluation and authorisation process being proposed by the European Commission in its White Paper on future chemicals policy, it is briefly reported. On specific issues, Cefic wants a risk-based approach to chemicals assessment and regulation realistic deadlines for the REACH process and exemption from REACH of finished articles, so that it applies only to substances marketed as substances or as constituents of a preparation. [Pg.52]

For the evaluation of g23 values, Peppas et al. first calculated the acid-base interaction parameter of every constituent amino acid residue, g23, according to the method of Lee and Richards [17]. [Pg.9]


See other pages where Constituent-based evaluation is mentioned: [Pg.229]    [Pg.231]    [Pg.185]    [Pg.187]    [Pg.229]    [Pg.231]    [Pg.185]    [Pg.187]    [Pg.2317]    [Pg.229]    [Pg.1311]    [Pg.231]    [Pg.187]    [Pg.2830]    [Pg.248]    [Pg.506]    [Pg.384]    [Pg.554]    [Pg.283]    [Pg.46]    [Pg.4]    [Pg.36]    [Pg.228]    [Pg.30]    [Pg.486]    [Pg.5]    [Pg.122]    [Pg.229]    [Pg.32]    [Pg.611]    [Pg.15]    [Pg.254]    [Pg.113]    [Pg.41]    [Pg.98]    [Pg.77]    [Pg.159]    [Pg.33]    [Pg.9]    [Pg.17]    [Pg.248]    [Pg.269]    [Pg.48]   
See also in sourсe #XX -- [ Pg.187 ]




SEARCH



Base constituents

© 2024 chempedia.info