Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Computer plot

Fig. 15 Computer plots for (a) absorption rate constant and (b) time of plasma peak. (From Ref. 31.)... [Pg.623]

Figure 5 is an ORTEP computer plot of the first 50 backbone carbons in a typical chain. Only the fluorine atoms of the sidechains are shown. The various hard sphere exclusions conspire dramatically to keep the fluorines well separated and the chain highly extended even without introducing any external perturbations. The characteristic ratio from the computer calculations is about 11.6 from data for poly(p-chlorostyrene), CR = I l.l, poly(p-bromostyrene), CR = 12.3, and poly(styrene), CR = 10.3 (all in toluene at 30°C), we expect the experimental value for the fluoro-polymer to be in the range of 10 to 12. [Pg.286]

Figure 5. ORTEP computer plot showing the positions of the fluorine atoms of the first 50 backbone carbons of a poly(p-fluorostyrene) chain. The excluded volumes used in the calculation keep the fluorines well separated. Figure 5. ORTEP computer plot showing the positions of the fluorine atoms of the first 50 backbone carbons of a poly(p-fluorostyrene) chain. The excluded volumes used in the calculation keep the fluorines well separated.
Using the computer, plot the titration curve and display it on the computer screen. If possible, print out a hard copy. [Pg.175]

Figure 6.21 Computed plot of the ratio of peak currents, /p(back//p(focwani), against log (kx) for an EC reaction, where t is the time-scale of the CV and k is the rate constant of the first-order homogeneous reaction. Notice how the plot has a similar shape to that shown in Figure 6.20, but the jc-axis is offset by the amount log k. Figure 6.21 Computed plot of the ratio of peak currents, /p(back//p(focwani), against log (kx) for an EC reaction, where t is the time-scale of the CV and k is the rate constant of the first-order homogeneous reaction. Notice how the plot has a similar shape to that shown in Figure 6.20, but the jc-axis is offset by the amount log k.
Drexel undergraduate students in both the lecture and the laboratory of physical chemistry have b n using TKISolver for such calculations as least squares fitting of experimental data, van der Waals gas calculations, and quantum mechanical computations (plotting particle-in-a-box wavefunctions, atomic orbital electron densities, etc.). I use TKISolver in lectures (on a Macintosh with video output to a 25" monitor) to solve simple equations and plot functions of chemical interest. [Pg.116]

Figure 5. Computer plots of experimental parameter, burn No, S, (a) Coal consumption and (b) input and output gas flow rates. Figure 5. Computer plots of experimental parameter, burn No, S, (a) Coal consumption and (b) input and output gas flow rates.
Figure 6, Computer plots of temperature data, (Top) Channel A, longitudinal temperature distribution (a) ignition point (b) V from ignition point (c) 2 from ignition point, (Top right) Section G, radial temperature distribution, (Bottom right) Fluid flow (a) inlet fluids (b) product gas (c)product gas off heat exchanger. Figure 6, Computer plots of temperature data, (Top) Channel A, longitudinal temperature distribution (a) ignition point (b) V from ignition point (c) 2 from ignition point, (Top right) Section G, radial temperature distribution, (Bottom right) Fluid flow (a) inlet fluids (b) product gas (c)product gas off heat exchanger.
Figure 2. Computer plot of a cadmium spectrum spiked with enriched... Figure 2. Computer plot of a cadmium spectrum spiked with enriched...
Empirical analysis of wave motion, fluid velocities. and stress can be made to enable vessel size, configuration and baffle system to be optimized. Analysis of the data Is made by direct visual observation of the fluid motion In the vessel, and computer plotting of wave profiles, fluid velocities, etc. [Pg.113]

Fig. 15.7 Stereoviews (left) and conventional computer plots (righi) of Fe3(CO)i (a. b) and Fci(CO)q (c, d). [From Johnson, B. F. G. Benfield, R. E. In Tuples lit (iiorpiinic und Orgattomctaflii Stereochemistry-, Geoffrey, G. L., Ed. Wiley New York. 1981. Reproduced with permission.]... Fig. 15.7 Stereoviews (left) and conventional computer plots (righi) of Fe3(CO)i (a. b) and Fci(CO)q (c, d). [From Johnson, B. F. G. Benfield, R. E. In Tuples lit (iiorpiinic und Orgattomctaflii Stereochemistry-, Geoffrey, G. L., Ed. Wiley New York. 1981. Reproduced with permission.]...
To answer the question above, whether the observed optical muta-rotation of galactose could be explained by the three-component model constrained to experimental ti/2% the optical rotatory values from the computations listed in Table II were plotted vs. time. The three plots did not differ significantly from each other, in spite of the variation in the ratio ki/ks. The plot for k /kz = 2 is compared with the experimental values in Figure 5. The observed rapid initial drop in rotation is not duplicated in the computed plot. No reasonable combination of... [Pg.36]

Figure 1. Computer plot of the light-scattering analysis of HEC before enaocellulase hydrolysis. (O) Experimental Kc/R values, (M) extrapolated values (by quadratic least squares analysis). The inverse of the Kc/Re intercept, Mw, equals 1,285,000. Figure 1. Computer plot of the light-scattering analysis of HEC before enaocellulase hydrolysis. (O) Experimental Kc/R values, (M) extrapolated values (by quadratic least squares analysis). The inverse of the Kc/Re intercept, Mw, equals 1,285,000.
Figure 2. Computer plot of the light-scattering analysis of HEC after endocellulase attach (O) Experimental Kc/Re values, extrapolated... Figure 2. Computer plot of the light-scattering analysis of HEC after endocellulase attach (O) Experimental Kc/Re values, extrapolated...
Figure 3. Computer plot obtained by isochronous interpolation of the experimental light-scattering data (O) of HEC during endocellulase attack. The Langrangian interpolation functions are given by the horizontal curves ana the isochronous interpolated Kc/Re values by A. The quadratic least squares extrapolations to zero angle ( ) are given by the... Figure 3. Computer plot obtained by isochronous interpolation of the experimental light-scattering data (O) of HEC during endocellulase attack. The Langrangian interpolation functions are given by the horizontal curves ana the isochronous interpolated Kc/Re values by A. The quadratic least squares extrapolations to zero angle ( ) are given by the...
Figure 5. v(t) — t (amplitude as a junction of time) and v(t) — 8(%) (phase-plane) diagrams of the coherent oscillation model (Model 2) with F0 == 0 = A. The computer plot shows a typical limit cycle oscillation. [Pg.228]

Figure 11. Resonance diagram (computer plot of the steady state amplitude of one oscillator as a function of the external frequency ) for 4 different values of the damping term ( = 0.5 1.2 1.3 2.0) ((I) oscillations around P0 (11) oscillations... Figure 11. Resonance diagram (computer plot of the steady state amplitude of one oscillator as a function of the external frequency ) for 4 different values of the damping term ( = 0.5 1.2 1.3 2.0) ((I) oscillations around P0 (11) oscillations...
Figures 14-18 are examples of the computer plots of selected data. These spectra have had dark current and fixed pattern noise subtracted "on-the-fly". (Both of these items are inherent in PDA s, the correction for which represents trivial implementation in terms of software and hardware). In some of the printouts, the individual diode levels can be seen representing 25 urn spatial resolution across the focal plane. The ordinate is quantified to only 12 bits while the PDA s themselves have a dynamic range of 14 bits. This was done for expediencey only. Figures 14-18 are examples of the computer plots of selected data. These spectra have had dark current and fixed pattern noise subtracted "on-the-fly". (Both of these items are inherent in PDA s, the correction for which represents trivial implementation in terms of software and hardware). In some of the printouts, the individual diode levels can be seen representing 25 urn spatial resolution across the focal plane. The ordinate is quantified to only 12 bits while the PDA s themselves have a dynamic range of 14 bits. This was done for expediencey only.
Figure 14. Computer plot of a partial spectrum of Tetrabromothiophede from... Figure 14. Computer plot of a partial spectrum of Tetrabromothiophede from...
Figure 16. Expanded computer plot of the mass range from 316 to 326, showing partial resolution of the —Br/—F doublets at m/e 317 and 319. The steps on the peaks represent the signal level in individual diodes. Figure 16. Expanded computer plot of the mass range from 316 to 326, showing partial resolution of the —Br/—F doublets at m/e 317 and 319. The steps on the peaks represent the signal level in individual diodes.
Figure 17. Expanded computer plot of the molecular ion region of Tetrabromo-thiophene from mass 388 to 407. Peaks at 391, 393, and 405 are caused by PFK. The peak at m/e 400 is slightly saturated. Figure 17. Expanded computer plot of the molecular ion region of Tetrabromo-thiophene from mass 388 to 407. Peaks at 391, 393, and 405 are caused by PFK. The peak at m/e 400 is slightly saturated.
Figure 18. Computer plot of a partial spectrum of a mixture of PFK and approximately 100 femtogram of cholesterol from mass 271 to mass 410 using an integration time of 100 milliseconds. Parent peak at m/e 386 is saturated. Figure 18. Computer plot of a partial spectrum of a mixture of PFK and approximately 100 femtogram of cholesterol from mass 271 to mass 410 using an integration time of 100 milliseconds. Parent peak at m/e 386 is saturated.

See other pages where Computer plot is mentioned: [Pg.429]    [Pg.142]    [Pg.140]    [Pg.198]    [Pg.199]    [Pg.241]    [Pg.241]    [Pg.241]    [Pg.241]    [Pg.394]    [Pg.2]    [Pg.328]    [Pg.40]    [Pg.150]    [Pg.674]    [Pg.96]    [Pg.248]    [Pg.237]    [Pg.89]   


SEARCH



Computer plot attack

Plotting program, computer

Plotting program, computer graphics

© 2024 chempedia.info