Senarmont compensators

A polarizing microscope for transmitted light usually has a polarizer at a fixed azimuth beneath the substage condenser, and an analyzer in the microscope tube above the objective. Typically, a compensator is inserted at 45° beneath the analyzer. Some compensators (such as the de Senarmont) are fixed in azimuth, and measurements are made with a rotary analyzer with a variable azimuth. For other compensators, the analyzer is fixed and the compensator is rotated or tilted to make measurements in the axis of the microscope. [Pg.154]

The optical system used to assess flow-induced birefringence consisted of a 2-mW polarized He-Ne laser focused by a condenser lens on the center of the flow field. The birefringence patterns are observed between crossed polars by using a quarter wave (X/4) retardation plate as a Senarmont compensator. The polarized laser has an extinction ratio of 100 1 the polarizer and analyzer are Carl Zeiss components with extinction ratios of approximately 10... [Pg.204]

A standard polarized-light microscope equipped with a Senarmont compensator, having magniflca tions up to 400X, and a rotatable analyzer with a graduated scale are used by the writer. All the obser vations are made with the use of the upper element of the substage condensing lens on the microscope. [Pg.47]

To measure alite birefringence using a Senarmont compensator and the upper element of the substage condensor, Ono recommends the following steps ... [Pg.50]

Insert the Senarmont compensator, properly oriented so that the darkness of the background results in cross-polarized light. Place a green filter in the path of the incoming light. The green filter facilitates observation of the alite crystal compensation point determined in the next step. [Pg.50]

Polarized-light microscope Senarmont compensator Reflected-light (metallo-graphic) microscope Petrographic slides (46x24 mm)... [Pg.170]

The Senarmont compensator has two parts, an accurate A/4 plate inserted above the specimen in the parallel 0° position and a rotating calibrated analyzer. Range is 150 nm. [Pg.69]

FIGURE 6.32 Polariscope arrangement for Senarmont compensation. (H. W. McKenzie and R. J. Hand, Basic Optical Stress Measurement in Glass, Society of Glass Technology, Sheffield, England, 1999, p. 41.)... [Pg.495]

Figure 11.9 (a) Edge stress meter principle www.sharplesstress.com/.) (c) Strainoptics Inc. with a Senarmont compensator, (b) Sharpies edge stress meter. (Photograph courtesy of edge stress meter. (Photograph courtesy Strainoptics Inc., www.strainoptics.com.)... [Pg.272]

Next consider a 1/4 wave plate (as used for a Senarmont compensator Chapter 11) inclined by 45° from principal directions 1 and 2 of a specimen, say, parallel to initial linear polarization (Figure A.3). The polarization vector... [Pg.306]

That is, a linear polarized light with polarization vector forming an angle of ///2 with initial polarization vector. Hence, an analyser allows determination of ///2 after rotating to darkness as done when using a Senarmont compensator. [Pg.307]


See other pages where Senarmont compensators is mentioned: [Pg.300]    [Pg.315]    [Pg.160]    [Pg.123]    [Pg.125]    [Pg.300]    [Pg.377]    [Pg.378]    [Pg.152]    [Pg.50]    [Pg.51]    [Pg.166]    [Pg.172]    [Pg.303]    [Pg.70]    [Pg.393]    [Pg.61]    [Pg.494]    [Pg.494]    [Pg.271]    [Pg.637]    [Pg.637]    [Pg.639]   
See also in sourсe #XX -- [ Pg.50 ]