Storage, columns

The columns should be stored in a neutral or slightly alkaline buffer (PBS or borate buffers are suitable) and sealed to prevent drying out. Storage at 4 °C in the presence of a preservative such as 0.02% sodium azide or 0.02% Thimerosal (Sigma) will prevent bacterial growth. It is important to protect the column from freezing as this will fracture agarose matrices. [Pg.330]


For long-term column storage, it is recommended to replace the mobile phase with distilled water with 0.05% sodium azide. The columns can then be stored at room temperature. For shorter storage times, e.g., a long weekend, the column should be stored in the mobile phase after making sure that the end plugs of the columns have been tightened well. [Pg.346]

Minimizing entails reducing the hazards by using smaller quantities of hazardous substances in the reactors, distillation columns, storage vessels, and pipelines. When possible, hazardous materials should be produced and consumed in situ. This minimizes the storage and transportation of hazardous raw materials and intermediates. [Pg.21]

The column should not be exposed to unnecessarily large volumes of solvent. Columns can be stored in a clean dry atmosphere, but they should be sealed by a flame or taped for very short periods of time. Some columns need to be stored in an atmosphere of nitrogen to avoid serious loss of selectivity. The manufacturer s instructions should be followed for column storage. [Pg.1041]

Analytical Properties Separation of bopindolol and also separation of pindolol after derivatization with isopropyl isocyanate separation of dl mixtures of enantiomers can be used on both the analytical and preparative scales changes in pH will cause this phase to leach from the column storage at 4°C is recommended Reference 1,2... [Pg.150]

Reactors, columns, storage tanks, process pots and pans. [Pg.262]

Fence wire Posts—columns Storage Tanks... [Pg.425]

Organic/aromatic Distillation/stripping columns, storage tanks Viton... [Pg.16]

Finally, wash the beads with 100 ml of column storage buffer (10 mM Tris-HCl, pH 7.5, 0.3 M NaCl, 1 mM EDTA, 0.02% NaNs). Resuspend the beads in the same buffer and store at 4°C. [Pg.332]

Oxygen degrades the stationary phases. For column storage it is recommended to seal the ends with a septum, and store in a dark place, typically the column box, to prevent stationary phase damage by oxidation, moisture and UV light. Not used installed GC columns should get a low carrier gas flow with spUt open at low flow as well (prepare a standby method at low oven temperature). Ah column manufacturers provide upper and lower temperature hmits for use of the individual columns and stationary phases ... [Pg.146]


See other pages where Storage, columns is mentioned: [Pg.68]    [Pg.119]    [Pg.35]    [Pg.264]    [Pg.302]    [Pg.68]    [Pg.35]    [Pg.33]    [Pg.36]    [Pg.804]    [Pg.807]    [Pg.35]    [Pg.51]    [Pg.269]    [Pg.68]    [Pg.141]    [Pg.382]    [Pg.1093]    [Pg.1095]    [Pg.330]    [Pg.732]    [Pg.735]    [Pg.330]    [Pg.494]    [Pg.189]   