Clamped circular diaphragm

Figure 2.13 Deflection of released membranes. (Left) Clamped circular diaphragm with thickness t and radius r subjected to a point load P at its center. (Middle) Clamped circular diaphragm subjected to a distributed load q N/m or Pa. (Right) Clamped square diaphragm with sides of length a subjected to a point load P at its center. (Reprinted with permission from Prof. Hiroshi Toshiyoshi, Institute of Industrial Science (IIS), The University of Tokyo, Japan.)... Figure 2.13 Deflection of released membranes. (Left) Clamped circular diaphragm with thickness t and radius r subjected to a point load P at its center. (Middle) Clamped circular diaphragm subjected to a distributed load q N/m or Pa. (Right) Clamped square diaphragm with sides of length a subjected to a point load P at its center. (Reprinted with permission from Prof. Hiroshi Toshiyoshi, Institute of Industrial Science (IIS), The University of Tokyo, Japan.)...
We next consider a small (linear) deflection of a clamped circular diaphragm under a distributed load as an example of a pressure sensor. The deflection d at the center of a stress-free clamped circular diaphragm with radius r is given by... [Pg.52]

A schematic cross-section diagram of a drop ejector fabricated in the PolyMUMPS process is shown in Figure 6.10. The actuator is a clamped circular diaphragm similar to the M-Test structure CD discussed in Chapter 2, Section 2.8. The membrane diaphragm is defined in the Polyl layer (2 pm) and is pulled down by application of a voltage to a... [Pg.128]

Figure 6.11 Formation of Newton s rings for a clamped-circular diaphragm defined in Polyl that has been pulled down by the application of a voltage to PolyO (Xerox MEMSJet). Figure 6.11 Formation of Newton s rings for a clamped-circular diaphragm defined in Polyl that has been pulled down by the application of a voltage to PolyO (Xerox MEMSJet).
Wilhams, J. L., J. H. Chen, and D. M. Belloh. 1992. Strain fields on cell stressing devices employing clamped circular elastic diaphragms as substrates. / Biomech Eng 114 377-84. [Pg.304]

In a diaphragm pressure gauge the elastic deflection of a circularly clamped metal disk is transferred to a pointer. Such devices are suitable for measuring ranges of 0-0.5 mbar and 0-70 bar [3]. For vacuum applications the range is 0-0.5 mbar and 0-1 bar vacuum. They are also suitable for differential pressure measurement if both sides of the diaphragm are connected with the respective measuring points. [Pg.603]


See other pages where Clamped circular diaphragm is mentioned: [Pg.29]    [Pg.45]    [Pg.29]    [Pg.45]    [Pg.144]    [Pg.224]    [Pg.449]    [Pg.367]    [Pg.76]   
See also in sourсe #XX -- [ Pg.45 , Pg.52 , Pg.128 ]