Another application of SFC-GC was for the isolation of chrysene, a poly aromatic hydrocarbon, from a complex liquid hydrocarbon industrial sample (24). A 5 p.m octadecyl column (200 cm X 4.6 mm i.d.) was used for the preseparation, followed by GC analysis on an SE-54 column (25 m X 0.2 mm i.d., 0.33 p.m film thickness). The direct analysis of whole samples transferred from the supercritical fluid chromatograph and selective and multi-heart-cutting of a particular region as it elutes from the SFC system was demonstrated. The heart-cutting technique allows the possibility of separating a trace component from a complex mixture (Figure 12.21). [Pg.327]

Figure 12.21 SFC-GC heait-cut analysis of chrysene from a complex hydrocarbon mixture (a) SFC ttace (UV detection) (b) GC trace without heait-cut (100% transfer) (c) GC ti ace of heatt-cut fraction (flame-ionization detection used for GC experiments). Reprinted from Journal of High Resolution Chromatography, 10, J. M. Levy et al., On-line multidimensional supercritical fluid chromatography/capillaiy gas cluomatography , pp. 337-341, 1987, with permission from Wiley-VCFI. Figure 12.21 SFC-GC heait-cut analysis of chrysene from a complex hydrocarbon mixture (a) SFC ttace (UV detection) (b) GC trace without heait-cut (100% transfer) (c) GC ti ace of heatt-cut fraction (flame-ionization detection used for GC experiments). Reprinted from Journal of High Resolution Chromatography, 10, J. M. Levy et al., On-line multidimensional supercritical fluid chromatography/capillaiy gas cluomatography , pp. 337-341, 1987, with permission from Wiley-VCFI.
Figure 12.23 SFC-SFC analysis, involving a rotaiy valve interface, of a standard coal tar sample (SRM 1597). Two fractions were collected from the first SFC separation (a) and then analyzed simultaneously in the second SFC system (h) cuts a and h are taken between 20.2 and 21.2 min, and 38.7 and 40.2 min, respectively. Peak identification is as follows 1, tii-phenylene 2, chrysene 3, henzo[g/ i]perylene 4, antliracene. Reprinted from Analytical Chemistry, 62, Z. Juvancz et al, Multidimensional packed capillary coupled to open tubular column supercritical fluid chromatography using a valve-switcliing interface , pp. 1384-1388, copyright 1990, with permission from the American Chemical Society. Figure 12.23 SFC-SFC analysis, involving a rotaiy valve interface, of a standard coal tar sample (SRM 1597). Two fractions were collected from the first SFC separation (a) and then analyzed simultaneously in the second SFC system (h) cuts a and h are taken between 20.2 and 21.2 min, and 38.7 and 40.2 min, respectively. Peak identification is as follows 1, tii-phenylene 2, chrysene 3, henzo[g/ i]perylene 4, antliracene. Reprinted from Analytical Chemistry, 62, Z. Juvancz et al, Multidimensional packed capillary coupled to open tubular column supercritical fluid chromatography using a valve-switcliing interface , pp. 1384-1388, copyright 1990, with permission from the American Chemical Society.

See other pages where Chrysenes, supercritical fluid is mentioned: [Pg.338]   


SEARCH



Chrysen

Chrysenes

© 2024 chempedia.info