Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chromatographic methods high performance liquid chromatography

For selective estimation of phenols pollution of environment such chromatographic methods as gas chromatography with flame-ionization detector (ISO method 8165) and high performance liquid chromatography with UV-detector (EPA method 625) is recommended. For determination of phenol, cresols, chlorophenols in environmental samples application of HPLC with amperometric detector is perspective. Phenols and chlorophenols can be easy oxidized and determined with high sensitivity on carbon-glass electrode. [Pg.129]

Despite the difficulties caused by the rapidly expanding literature, the use of chiral stationary phases (CSPs) as the method of choice for analysis or preparation of enantiomers is today well established and has become almost routine. It results from the development of chiral chromatographic methods that more than 1000 chiral stationary phases exemplified by several thousands of enantiomer separations have been described for high-performance liquid chromatography (HPLC). [Pg.94]

Bogusz, M., Franke, J. P., de Zeeuw, R. A., and Erkens, M., An overview of the standardization of chromatographic methods for screening analysis in toxicology by means of retention indices and secondary standards. Part II. High performance liquid chromatography, Fresenius ]. Anal. Chem., 347, 73, 1993. [Pg.195]

Fan used a high performance liquid chromatographic method for the qualitative and quantitative analysis of miconazole [59], Miconazole sample was dissolved in methanol and determined by high performance liquid chromatography using methanol-water (75 25) as the mobile phase and ultraviolet detection at 214 nm, the recovery was more than 99.4% and the accuracy was satisfactory for the qualitative and quantitative analysis. [Pg.47]

High performance liquid chromatography-mass spectrometric methods Nitin et al. [75] developed and validated a sensitive and selective liquid chromatography-tandem mass spectrometric method (LC MS MS) for the simultaneous estimation of bulaquine and its metabolites primaquine in monkey plasma. The mobile phase consisted of acetonitrile ammonium acetate buffer (20 mM, pH 6) (50 50, v/v) at a flow rate of 1 mL/min. The chromatographic separations were achieved on two Spheri cyano columns (5 pm, 30 cm x 4.6 mm), connected in... [Pg.187]


See other pages where Chromatographic methods high performance liquid chromatography is mentioned: [Pg.80]    [Pg.80]    [Pg.226]    [Pg.622]    [Pg.5]    [Pg.181]    [Pg.138]    [Pg.110]    [Pg.222]    [Pg.96]    [Pg.120]    [Pg.61]    [Pg.77]    [Pg.276]    [Pg.33]    [Pg.65]    [Pg.378]    [Pg.66]    [Pg.102]    [Pg.109]    [Pg.445]    [Pg.286]    [Pg.84]    [Pg.54]    [Pg.724]    [Pg.1130]    [Pg.231]    [Pg.232]    [Pg.35]    [Pg.147]    [Pg.288]    [Pg.47]    [Pg.47]    [Pg.47]    [Pg.48]    [Pg.48]    [Pg.49]    [Pg.50]    [Pg.51]    [Pg.55]    [Pg.188]    [Pg.189]    [Pg.191]   


SEARCH



Chromatographic methods

Chromatographic performance

High Performance Liquid Chromatographic Methods

High methods

High performance liquid chromatography method

High-performance liquid chromatograph

High-performance liquid chromatographic

High-performance liquid methods

Liquid chromatograph

Liquid chromatographic

Liquid chromatographic methods

Liquid chromatography methods

Method performance

Methods chromatography

© 2024 chempedia.info