Even with the superposition of the ac with a cathodic protection current, a large part of the anodic half wave persists for anodic corrosion. This process cannot be detected by the normal method (Section 3.3.2.1) of measuring the pipe/soil potential. The IR-free measurable voltage between an external probe and the reference electrode can be used as evidence of more positive potentials than the protection potential during the anodic phase. Investigations have shown, however, that the corrosion danger is considerably reduced, since only about 0.1 to 0.2% contributes to corrosion. [Pg.151]

Different microstructural regions in a material which has an almost uniform composition can also lead to the formation of corrosion cells (e.g., in the vicinity of welds). Basically, corrosion cells can be successfully overcome by cathodic protection. However, in practice, care has to be taken to avoid electrical shielding by large current-consuming cathode surfaces by keeping the area as small as possible. In general, with mixed installations of different metals, it must be remembered that the protection potentials and the protection range depend on the materials (Section 2.4). This can restrict the use of cathodic protection or make special potential control necessary. [Pg.395]

If — during this process — the Cu2+-concentration decreases, the mixed potential will shift along the cathodic partial current density curve (like a polarographic curve in this example) toward the equilibrium potential of the zinc amalgam, in case the amalgam reservior is large enough. [Pg.231]

The limiting cathodic current, region 1 in Figure 2.91, corresponds to values of so large that [O]0 [O ]. Hence, the cathodic limiting current, /u, is given by ... [Pg.184]

Large Anodic Current. When r] has large positive values, the second exponential term in Eq. (6.45) (corresponding to the cathodic partial current density) decreases while the first term (corresponding to the anodic partial reaction) increases, resulting in i. Thus, the smaller term. [Pg.89]

At equilibrium (i.e., no current) there exist dynamic currents, measured in amps, at each electrode and are a fundamental characteristic of electrode behavior. The anode and cathode exchange current densities can be defined as the rate of oxidation and reduction respectively. The exchange current density is a measure of the electrode s ability to transfer electrons and occurs equally in both directions resulting in no net change in composition of the electrode.22 A large exchange current density represents an electrode with fast kinetics where there is a lot of simultaneous electron transfer. A small exchange current density has slow kinetics and the electron transfer rate is less. [Pg.53]


See other pages where Cathode, large current is mentioned: [Pg.2873]    [Pg.425]    [Pg.132]    [Pg.100]    [Pg.2429]    [Pg.234]    [Pg.309]    [Pg.208]    [Pg.225]    [Pg.272]    [Pg.18]    [Pg.1304]    [Pg.215]    [Pg.56]    [Pg.315]    [Pg.105]    [Pg.106]    [Pg.343]    [Pg.177]    [Pg.216]    [Pg.716]    [Pg.231]    [Pg.215]    [Pg.308]    [Pg.562]    [Pg.74]    [Pg.90]    [Pg.102]    [Pg.189]    [Pg.18]    [Pg.179]    [Pg.352]    [Pg.98]    [Pg.524]    [Pg.442]    [Pg.2184]    [Pg.259]    [Pg.50]    [Pg.308]    [Pg.1253]    [Pg.29]    [Pg.125]   