Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Capillary, flow alignment

As demonstrated, Eq. (7) gives complete information on how the weight fraction influences the blend viscosity by taking into account the critical stress ratio A, the viscosity ratio 8, and a parameter K, which involves the influences of the phenomenological interface slip factor a or ao, the interlayer number m, and the d/Ro ratio. It was also assumed in introducing this function that (1) the TLCP phase is well dispersed, fibrillated, aligned, and just forms one interlayer (2) there is no elastic effect (3) there is no phase inversion of any kind (4) A < 1.0 and (5) a steady-state capillary flow under a constant pressure or a constant wall shear stress. [Pg.687]

HL/HB patterning can be utilized in applications, including surface-directed capillary flow [7], controlled biomolecular adsorption, microgel synthesis, liquid-assisted molding, liquid-liquid extraction [9], self-alignment, and humidity extraction. [Pg.1331]

The last part of the book deals with Hquids crystals and ceramic microelectronic devices. Chapter 12, by Mendoza et al. reviews recent theoretical results on the rheology of systems consisting of a flow-aligning nematic contained in cells and capillaries under a variety of different flow conditions and under the action of applied electric fields. Finally, chapter 13, by Alias and Shapee, stresses the impact of silver paste rheology in the fabrication of ceramic microelectronic devices (low temperature co-fired ceramic LTCC devices). [Pg.348]

Figure 2. Flow in a flat capillary with weak anchoring at the capillary walls. The director orientation deviates from the direction of the magnetic field due to flow alignment. Upper part velocity profile, lower part vector field of the director for d>o = 90°. <1 ... Figure 2. Flow in a flat capillary with weak anchoring at the capillary walls. The director orientation deviates from the direction of the magnetic field due to flow alignment. Upper part velocity profile, lower part vector field of the director for d>o = 90°. <1 ...
The drop in pressure when a stream of gas or liquid flows over a surface can be estimated from the given approximate formula if viscosity effects are ignored. The example calculation reveals that, with the sorts of gas flows common in a concentric-tube nebulizer, the liquid (the sample solution) at the end of the innermost tube is subjected to a partial vacuum of about 0.3 atm. This vacuum causes the liquid to lift out of the capillary, where it meets the flowing gas stream and is broken into an aerosol. For cross-flow nebulizers, the vacuum created depends critically on the alignment of the gas and liquid flows but, as a maximum, it can be estimated from the given formula. [Pg.141]

The improved design of the gating interface resulted in precise alignment of the two capillaries. A colored dye solution was added to the HPLC eluent to allow for du cct observation of the flow gating and injection processes. Through observation of the movement of the dye through the interface, it was possible to ensure that the electrokinetic injections were performed correctly. Troubleshooting had been a... [Pg.210]

Realistically, the flow path through the seal volume will not consist of uniform cylindrical capillaries aligned normal to the seal. The actual leakage paths will be longer, less direct (convoluted), and of nonuniform cross-section. To account for these effects, the effective path length is increased by a tortuosity factor, t, typically having a value in the range of 2 to 3. [Pg.223]

The limit of detection (LOD) is that concentration which can be differentiated from a blank, while the limit of quantitation (LOQ) is the lowest concentration which can be determined with an acceptable accuracy and precision. It is important to realise that with most instruments, when a capillary is replaced, in most cases the detector flow cell is also replaced since detection takes place on-column. In this case, although the entire method need not be re-validated, the limits of detection and limits of quantitation, if these are appropriate to the method validation being undertaken, should be redetermined. Minor variations in capillary alignment can be sufficient to produce significant changes in detector response and sensitivity. This may not be necessary when using a decoupled detection cell. [Pg.21]


See other pages where Capillary, flow alignment is mentioned: [Pg.929]    [Pg.929]    [Pg.109]    [Pg.173]    [Pg.77]    [Pg.108]    [Pg.71]    [Pg.491]    [Pg.244]    [Pg.336]    [Pg.464]    [Pg.295]    [Pg.1127]    [Pg.1136]    [Pg.1137]    [Pg.258]    [Pg.145]    [Pg.154]    [Pg.155]    [Pg.77]    [Pg.89]    [Pg.1002]    [Pg.53]    [Pg.480]    [Pg.498]    [Pg.14]    [Pg.266]    [Pg.24]    [Pg.40]    [Pg.166]    [Pg.208]    [Pg.169]    [Pg.103]    [Pg.220]    [Pg.347]    [Pg.610]    [Pg.24]    [Pg.233]    [Pg.68]   
See also in sourсe #XX -- [ Pg.459 ]

See also in sourсe #XX -- [ Pg.459 ]




SEARCH



Capillary flow

© 2024 chempedia.info