Concentration Broadening

From the equation for polymer network motion to broaden concentration fluctuations of the longitudinal mode with the vector q (Candau cl al., 1982), one obtain... [Pg.365]

Figure 5.11 Schematic flowchart showing the stages involved in an interdiffusion experiment (68). The slices are scanned in an IR microdensitometer to obtain the broadened concentration profile, from which D is evaluated. Figure 5.11 Schematic flowchart showing the stages involved in an interdiffusion experiment (68). The slices are scanned in an IR microdensitometer to obtain the broadened concentration profile, from which D is evaluated.
Apart from the natural lifetime due to spontaneous emission, both uni- and bimolecular processes can contribute to the observed value of T. One important contribution comes from coiiisionai broadening, which can be distmguished by its pressure dependence (or dependence upon concentration [M] of tlie collision partner) ... [Pg.2140]

One contribution to band broadening in which solutes diffuse from areas of high concentration to areas of low concentration. [Pg.560]

Poly(ethyl methacrylate) (PEMA) yields truly compatible blends with poly(vinyl acetate) up to 20% PEMA concentration (133). Synergistic improvement in material properties was observed. Poly(ethylene oxide) forms compatible homogeneous blends with poly(vinyl acetate) (134). The T of the blends and the crystaUizabiUty of the PEO depend on the composition. The miscibility window of poly(vinyl acetate) and its copolymers with alkyl acrylates can be broadened through the incorporation of acryUc acid as a third component (135). A description of compatible and incompatible blends of poly(vinyl acetate) and other copolymers has been compiled (136). Blends of poly(vinyl acetate) copolymers with urethanes can provide improved heat resistance to the product providing reduced creep rates in adhesives used for vinyl laminating (137). [Pg.467]

In numerous applications of polymeric materials multilayers of films are used. This practice is found in microelectronic, aeronautical, and biomedical applications to name a few. Developing good adhesion between these layers requires interdiffusion of the molecules at the interfaces between the layers over size scales comparable to the molecular diameter (tens of nm). In addition, these interfaces are buried within the specimen. Aside from this practical aspect, interdififlision over short distances holds the key for critically evaluating current theories of polymer difllision. Theories of polymer interdiffusion predict specific shapes for the concentration profile of segments across the interface as a function of time. Interdiffiision studies on bilayered specimen comprised of a layer of polystyrene (PS) on a layer of perdeuterated (PS) d-PS, can be used as a model system that will capture the fundamental physics of the problem. Initially, the bilayer will have a sharp interface, which upon annealing will broaden with time. [Pg.667]

Determination of concentration profiles from the raw data can be more complicated when protons are used as the incident particles. The energy loss ( dE/ die) is smaller for protons and straggling effects are more important. The observed profile A (AJ)) is a convolution of the actual concentration profile C x with a depth resolution function (x, Eq), which broadens with increasing x roughly as Jx- Hence, resolution deteriorates with depth. However, near-surface resolution for resonant profiling may be on the order of tens of A. [Pg.684]

Errors in the molecular weight data from HPSEC are usually due to improperly prepared samples, column dispersity, or flow rate variations. The sample to be analyzed should be completely dissolved in the mobile phase and filtered prior to injection onto the column. A plugged column inlet frit will invalidate results. In addition, do not load the column with excess sample. Column overloading affects the accuracy of data by broadening peaks, reducing resolution, and increasing elution volume. For best results, the concentration of the injected sample should be as low as possible while still providing adequate... [Pg.82]

In order to achieve the best efficiency the SEC column should be operated at optimized operating parameters. The most important ones are flow rate [cf. van Deemter equation for band-broadening effects (21)], sample viscosity (depends on molar mass and concentration of the sample), and injection volume (7). [Pg.282]

Sample loading must be reduced in accordance with the column inside diameter. Polymers exhibit high solution viscosity, and in order to avoid band broadening due to viscous streaming the sample concentration must be reduced for narrow-bore columns. Overloading effects become noticeable at much lower concentrations using 4.6-mm columns compared to 7.5-mm columns because of the effective sample concentration in a smaller volume column. [Pg.365]

This result reveals that exciplex formation plays a principal role in the initiation of polymerization. Since the absorption band is broadened toward longer wavelengths as the result of formation of CTC between AN and aniline, a certain concentration of aniline can be chosen so that 365-nm light is absorbed only by the CTC but not by the aniline molecule. Therefore, in this case the photopolymerization may be ascribed to the CTC excitation selected. For example, a 5 x 10 mol/L aniline solution in AN could absorb light of 365 nm, while solutions in DMF or cyclohexane with the same concentration will show no absorption. Obviously, in this case the polymerization of AN is caused by CTC excitation. The rates of polymerization for different amines were found to be in the following order (Table 12) ... [Pg.238]

Chemical and physical nonlinearities are caused by interactions among the components of a system. They include such effects as peak shifting and broadening as a function of the concentration of one or more components in the sample. Instrumental nonlinearities are caused by imperfections and/or nonideal behavior in the instrument. For example, some detectors show a... [Pg.44]

Besides the ever-broadening scientific investigations which are being conducted world-wide in the field of inorganic peroxide compds, it is also necessary to concentrate in the applied field on the sound development of continuous, safe, efficient and economical prodn methods so as to increase the utilization of inorganic peroxides... [Pg.664]


See other pages where Concentration Broadening is mentioned: [Pg.239]    [Pg.210]    [Pg.915]    [Pg.239]    [Pg.210]    [Pg.915]    [Pg.721]    [Pg.1438]    [Pg.2439]    [Pg.548]    [Pg.560]    [Pg.774]    [Pg.638]    [Pg.651]    [Pg.263]    [Pg.513]    [Pg.303]    [Pg.314]    [Pg.45]    [Pg.56]    [Pg.437]    [Pg.139]    [Pg.105]    [Pg.193]    [Pg.428]    [Pg.228]    [Pg.34]    [Pg.70]    [Pg.431]    [Pg.615]    [Pg.616]    [Pg.173]    [Pg.214]    [Pg.165]    [Pg.69]    [Pg.708]    [Pg.190]    [Pg.92]    [Pg.66]    [Pg.31]    [Pg.156]   