Backup Flooding

Downcomer Backup Flood. For downcomer backup. Equation 4 can be used. Reference 15 states that if the downcomer backup for valve trays exceeds 40% of tray spacing for high vapor density systems I3.01bs/ft-), 50% for medium vapor densities, and 60% for vapor densities... [Pg.301]

Downcomer backup flooding results from pressure drop at bottom outlet of downcomer, causes liquid to backup in the downcomer and flood the tray above. Generally the cause is due to excessive tray pressure drop. [Pg.212]

Downcomer Backup Flooding Aerated liquid backs up in the downcomer because of tray pressure drop, liquid height on the tray, and frictional losses in the downcomer apron (Fig. 14-32). All these increase with increasing liquid rate. Tray pressure drop also increases as the gas rate rises. When the backup of aerated liquid exceeds the tray spacing, liquid accumulates on the tray above, causing downcomer backup flooding. [Pg.38]

Downcomer backup flooding occurs when the backup of aerated liquid in the downcomer exceeds the available tray spacing. Downcomer backup can be calculated by adding the clear liquid height on the tray, the liquid backup caused by the tray pressure drop, and the liquid backup caused by the friction loss at the downcomer outlet. The downcomer backup is then divided by an aeration factor to give the aerated liquid backup. [Pg.23]

Tray area is usually determined from an entrainment flooding correlation. Trays are normally designed to operate at 80 to 85% of flood at the maximum expected throughput. Downcomer area is usually determined from the downcomer choke criteria. The design is then checked to ensure that downcomer backup flood does not occur. [Pg.23]

Figure 6.7 Common flooding mechanisms in tray columns, (a) Spray entrainment flood (ft) froth ontrainment flood (c) downcomer backup flood Id) downcomer choke flood. (Parle a and ft reproduced from Dr. D. C. Hausch, Discussion of Paper Presented In the Fifth Session, Proceedings of the International Symposium on Distiliation, the Institution of Chemical Engineers (London), I960, reprinted courtesy of the Institution of Chemical Engineers, UK- Parts c and d from H. Z. Kister. Distillation Operation. Copyright C 1990 6y McGraw-Hill, Inc. reprinted by permission.)... Figure 6.7 Common flooding mechanisms in tray columns, (a) Spray entrainment flood (ft) froth ontrainment flood (c) downcomer backup flood Id) downcomer choke flood. (Parle a and ft reproduced from Dr. D. C. Hausch, Discussion of Paper Presented In the Fifth Session, Proceedings of the International Symposium on Distiliation, the Institution of Chemical Engineers (London), I960, reprinted courtesy of the Institution of Chemical Engineers, UK- Parts c and d from H. Z. Kister. Distillation Operation. Copyright C 1990 6y McGraw-Hill, Inc. reprinted by permission.)...
Downcomer backup flooding occurs when the backup of aerated liquid in the downcomer exceeds the tray spacing, i.e.,... [Pg.283]

Summary. The third trial checks well against the various hydraulic criteria. Column capacity is limited by downcomer backup flood in the bottom section center-to-side trays (i.e., side downcomers). All trays will operate in the emulsion regime. [Pg.357]

Capacity restriction mechanism(s). Column throughput is restricted by one of several different mechanisms. These include spray entrainment flooding, froth entrainment flooding, downcomer backup flooding, downcomer choke flooding, excessive entrainment and excessive pressure drop. Optimum tray and downcomer layouts vary with the mech-... [Pg.141]

Downcomer backup flooding occurs when the backup of aerated liquid... [Pg.283]

Thus, there will be no downcomer backup flood. [Pg.268]

Downcomer Backup Limit The maximum downcomer liquid height allowable is set by the tray spacing and outlet weir height. Downcomer backup flooding occurs when the liquid froth in the downcomer reaches the tray above. Assume the maximum backup limit as 80% and the froth density q) = 0.6 (Kister, 1992). Applying equation (12.23) yields... [Pg.272]