Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Air-heating system

Pressures induced by fans or by appliances such as combusnon devices or forced-air heating systems. [Pg.1084]

A hot-water heating system forces water into pipes, or arrangements of pipes called registers that warm from contact with warm water. Air in the room warms from contact with the pipes. Usually, the pipes are on the floor of a room so that warmer, less dense air around the pipes rises somewhat like a helium-filled balloon rises in air. The warmer air cools as it mixes with cooler air near the ceiling and falls as its density increases. This process is called convection and the moving air is referred to as convection current. The process of convection described here is pipe-to-air and usually does a better job of heating evenly than in an air-to-air convection system—the circulation of air by fans as in a forced-air heating system. [Pg.602]

High-temperature high-velocity warm air heating systems 27/458... [Pg.401]

The first ground-source heat pump was installed in Indianapolis, Indiana in the home of Robert C. Webber, an employee of the Indianapolis Power and Light Company. It was a 2.2 kW compressor hooked to a direct expansion ground coil system in trenches supplying heat to a warm air heating system. The installation was monitored beginning October 1, 1945 and this is the first day of ground source heat pump operation documented in literature [2],... [Pg.5]

Power-vented or dedicated outdoor combustion air heating systems. [Pg.1298]

Consider the air-heating system used to regulate the temperature in a... [Pg.29]

Perimeter Heating - A term applied to warm-air heating systems that deliver heated air to rooms by means of registers or baseboards located along exterior walls. [Pg.391]

Radiant Floor - A type of radiant heating system where the building floor contains channels or tubes through which hot fluids such as air or water are circulated. The whole floor is evenly heated. Thus, the room heats from the bottom up. Radiant floor heating eliminates the draft and dust problems associated with forced air heating systems. [Pg.400]

Air can also be used as the heat transfer fluid in collectors built for this purpose. The heat store in this case will most often be a rock bin or a rock bed, that is, an insulated container filled with crushed rocks or pebbles (called a bin if it is an upright container or a bed if it is a shallow layer under the floor). The solar heated air will warm the rocks, and at a later time the air flow in the distribution circuit will remove this heat and transport it to the spaces where it is needed. Figure 11 shows a basic air heating system diagram. Instead of small pipes, more bulky air ducts must be used, and instead of pnmps, fans, or blowers. A much larger quantity of air must be circulated than the volume of... [Pg.225]

The typical dehumidifying drying system consists of the process air fan, dehumidifier, an electric or gas-fired air heating system, a control system, the drying hopper, and a process air filter. The dehumidifier itself includes the desiccant regeneration system. [Pg.519]


See other pages where Air-heating system is mentioned: [Pg.602]    [Pg.602]    [Pg.603]    [Pg.603]    [Pg.605]    [Pg.401]    [Pg.412]    [Pg.143]    [Pg.313]    [Pg.63]    [Pg.134]    [Pg.48]    [Pg.56]    [Pg.332]    [Pg.533]    [Pg.366]    [Pg.307]    [Pg.296]    [Pg.554]    [Pg.313]    [Pg.158]    [Pg.122]    [Pg.122]   
See also in sourсe #XX -- [ Pg.38 ]




SEARCH



Air Heating

Air conditioning and heating systems

HVAC (Heating, Ventilation, and Air Conditioning) System

Heat systems

Heating, ventilating, and air conditioning system

Heating, ventilation and air conditioning system

© 2024 chempedia.info