Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Water minimization limiting conditions

Polymer Electrolyte Fuel Cell. The electrolyte in a PEFC is an ion-exchange (qv) membrane, a fluorinated sulfonic acid polymer, which is a proton conductor (see Membrane technology). The only Hquid present in this fuel cell is the product water thus corrosion problems are minimal. Water management in the membrane is critical for efficient performance. The fuel cell must operate under conditions where the by-product water does not evaporate faster than it is produced because the membrane must be hydrated to maintain acceptable proton conductivity. Because of the limitation on the operating temperature, usually less than 120°C, H2-rich gas having Htde or no ([Pg.578]

On some group and district heating schemes, outlet-limiting valves which permit flow only when the water temperature has dropped to a specified low level are used. This procedure minimizes the water quantity to be pumped and permits indicative heat metering by water quantity alone. In such cases, care must be taken to size emitters to suit the available water temperatures. The effect of low water velocities through the emitter must also be taken into consideration, since the heat output of some convective appliances is greatly reduced under such conditions. [Pg.409]

This aromatic alcohol has been an effective preservative and still is used in several ophthalmic products. Over the years it has proved to be a relatively safe preservative for ophthalmic products [138] and has produced minimal effects in various tests [99,136,139]. In addition to its relatively slower rate of activity, it imposes a number of limitations on the formulation and packaging. It possesses adequate stability when stored at room temperature in an acidic solution, usually about pH 5 or below. If autoclaved for 20-30 minutes at a pH of 5, it will decompose about 30%. The hydrolytic decomposition of chlorobutanol produces hydrochloric acid (HC1), resulting in a decreasing pH as a function of time. As a result, the hydrolysis rate also decreases. Chlorobutanol is generally used at a concentration of 0.5%. Its maximum water solubility is only about 0.7% at room temperature, which may be lowered by active or excipients, and is slow to dissolve. Heat can be used to increase dissolution rate but will also cause some decomposition and loss from sublimation. Concentrations as low as 0.125% have shown antimicrobial activity under the proper conditions. [Pg.434]


See other pages where Water minimization limiting conditions is mentioned: [Pg.362]    [Pg.130]    [Pg.85]    [Pg.391]    [Pg.147]    [Pg.297]    [Pg.127]    [Pg.483]    [Pg.16]    [Pg.360]    [Pg.238]    [Pg.547]    [Pg.113]    [Pg.8]    [Pg.78]    [Pg.131]    [Pg.130]    [Pg.70]    [Pg.777]    [Pg.241]    [Pg.243]    [Pg.355]    [Pg.404]    [Pg.169]    [Pg.280]    [Pg.350]    [Pg.496]    [Pg.43]    [Pg.74]    [Pg.247]    [Pg.180]    [Pg.418]    [Pg.216]    [Pg.319]    [Pg.393]    [Pg.489]    [Pg.91]    [Pg.348]    [Pg.490]    [Pg.421]    [Pg.422]    [Pg.45]    [Pg.59]    [Pg.99]    [Pg.106]    [Pg.373]    [Pg.32]   
See also in sourсe #XX -- [ Pg.618 ]




SEARCH



Water limitation

Water minimization

© 2024 chempedia.info