Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Vacuum taps

IkXj, WL alternative working lines. The second one is, of course, optional. J -Ji cone-and-socket joints, at least B.19, preferably B.24. J and can, of course, be replaced by fused junctions. T, hollow key vacuum taps of... [Pg.31]

Fig. 3.3. Pressure equalisation burette in a device for potentiometric titration. For full details of operation see original publication. A break-seal ampoule containing the titrating solution B which reacts with the contents of break-seal ampoules P in reactor R, C sintered filter, Z) 10 ml burette, E 2 mm capillary, F capillary tip, Pt wires from electrodes leading to potentiometer. T, T, 7 PTFE taps, 7J three-way glass vacuum tap. Fig. 3.3. Pressure equalisation burette in a device for potentiometric titration. For full details of operation see original publication. A break-seal ampoule containing the titrating solution B which reacts with the contents of break-seal ampoules P in reactor R, C sintered filter, Z) 10 ml burette, E 2 mm capillary, F capillary tip, Pt wires from electrodes leading to potentiometer. T, T, 7 PTFE taps, 7J three-way glass vacuum tap.
Fig. 4.3. The rig for purification of a liquid by sodium vapour. See text for details. The O are glass vacuum taps of large ( > 5 mm) bore. Fig. 4.3. The rig for purification of a liquid by sodium vapour. See text for details. The O are glass vacuum taps of large ( > 5 mm) bore.
General techniques for high vacuum systems have been covered in detail in various reviews, in particular conventional high vacuum taps and their lubri-... [Pg.6]

When nitrogen has been passed into the system for a third time, place the polymerization tube into the liquid nitrogen Dewar and evacuate the manifold by closing the nitrogen supply and opening the vacuum tap. [Pg.54]

Vacuum within the insulation was higher than that required for negligible gas conduction. It should have been less than 0.1 rather than about 0.5 /x Hg, as measured at the vacuum tap. [Pg.42]

The foams were tested in a cylindrical calorimeter similar to the one shown in Fig. 2. The unit consists basically of two concentric stainless steel cans separated by a 2)4-in. thickness of the test foam. To minimize the end effects of a calorimeter of this type, the upper end was insulated with a high-vacuum space, while the lower end was insulated with an extra-thick section of the test foam itself. Fill and vent lines, as well as suitable vacuum taps were provided in the... [Pg.273]