Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Unit Cell Refinement

Nearly all unit cell refinement programs assume that a list of peak positions will be provided in some form. A personal favorite for quick unit cell refinement is the graphical Celref for Windows software of Jean Laugier and Bernard Bochu. Celref also understands space groups and includes a facility to automatically match HKL positions to observed peaks. For use of internal standard, the XLAT software of Bernhard Rupp, despite its age, is very effective. However, [Pg.522]

ABSEN a PC computer program for listing systematic absences and space group determination, P. McArdle, [Pg.523]

International Tables for Crystallography Volume A Space group symmetry, ed. Theo Hahn, Published for the International Union of Crystallography by Springer. Fifth edition, April 2002, ISBN 0 7923 6590 9 ISOTROPY, H. T. Stokes and D. M. Hatch, (2002), http // stokes.byu.edu/isotropy.html [Pg.523]

MAUD (Material Analysis Using Diffraction) a user friendly Java program for Rietveld Texture Analysis and more, [Pg.523]


Pawley, G.S. Unit-cell refinement from powder diffraction scans. J.Appl. Cryst. 14 357-... [Pg.419]

Figure 1. Results of full pattern fitting (after [53]) of the PXD pattern of an acid-treated phase A sample, based on an orthorhombic unit cell (refined lattice constants a = 7.940(3)A, b = 10.338(4)A, c = 11.591(5)A). The low angle peaks are somewhat asymmetric and are hence not fitted well by the assumed symmetric pseudo-Voigt peak shape. Figure 1. Results of full pattern fitting (after [53]) of the PXD pattern of an acid-treated phase A sample, based on an orthorhombic unit cell (refined lattice constants a = 7.940(3)A, b = 10.338(4)A, c = 11.591(5)A). The low angle peaks are somewhat asymmetric and are hence not fitted well by the assumed symmetric pseudo-Voigt peak shape.
Pawley, G.S., Unit Cell Refinement from Powder Diffraction Scans, Ibid. 14 357 (1981). [Pg.32]

The sample displacement parameter Ss calculated for each particular case from the displacement (s, in mm) obtained during unit cell refinement as Ss = -36000s/(7tR) or Ss = -144s/7T for the goniometer radius R = 250 mm. [Pg.643]

LAPOD Langford Unit Cell Refinement WWW. ccp 14. ac. uk/ccp/web-mirrors/lapod-langford/... [Pg.302]

XLAT Rupp Unit cell refinement ftp //www-structure.llnl.gov/... [Pg.302]

Full profile fitting can be useful for various tasks including unit cell refinement involving peak overlap, space group assignment, extracting intensities prior to structure solution, and pre-structure refinement fitting of the powder pattern. The two main methods are listed below. [Pg.523]

Table 17.15 Available unit cell refinement software. Table 17.15 Available unit cell refinement software.
Unit cell refinement from powder diffraction data the use of regression diagnostics, T. J. B. [Pg.527]

PAW 81] PAWLEY G.S., Unit cell refinement from powder dif action scans , J. Appl. Cryst, vol. 14, p. 357-361,1981. [Pg.337]

There are problems with the unit cell refinement. [Pg.122]


See other pages where Unit Cell Refinement is mentioned: [Pg.645]    [Pg.337]    [Pg.444]    [Pg.562]    [Pg.572]    [Pg.302]    [Pg.323]    [Pg.522]    [Pg.523]    [Pg.527]    [Pg.27]    [Pg.495]   


SEARCH



Cell, refining

UNIT CELL DETERMINATION AND REFINEMENT

Unit cell refinement software