Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

TRIM method

The only difference between the steps along the image mode and the transverse modes is the sign of the level shift. The level shift p < —A.i is determined such that the step is to the boundary of the trust region. Equation (6.18) forms the basis for the trust region image minimization (TRIM) method for calculating saddle points.20... [Pg.321]

We can now see the difference between the GE and TRIM methods. In the GE algorithm we first minimize the transverse modes and then maximize the reaction mode. In the TRIM method we minimize and maximize simultaneously by introducing an auxiliary function Eq. (6.21). The underlying idea of the GE method are lines connecting stationary points. The idea behind the TRIM method is an auxiliary function (the image function) whose minima coincide with the saddle points of the original function. [Pg.322]

A difficulty with this local approach to dynamical correlation is that, in Moller-Plesset theory, for example, the zero-order Fock operator is no longer diagonal in the space of the Slater determinants, making the application of such theories slightly more complicated than theories based on canonical orbitals. Currently, the development of local correlation methods is an active area of research [57-63]. The diatomics-inmolecules (DIM) method and the triatomics-in-molecules (TRIM) method, for instance, recover typically 95% and 99.7%, respectively, of the full MP2 correlation energy [63]. By means of a linear scaling local variant of the CCSDT method,... [Pg.79]

Figure 4.2 Photomask images for the photoresist patterns of the PDMS emitter device produced by the trimming method. (Reprinted with permission from ref. 22.)... Figure 4.2 Photomask images for the photoresist patterns of the PDMS emitter device produced by the trimming method. (Reprinted with permission from ref. 22.)...
The production of the photomask designs for the photoresist patterns (Figure 4.4) and the processes for producing the photoresist patterns were the same as for the trimming method. [Pg.76]

Four-Channel PDMS Emitter Prepared by the Trimming Method... [Pg.85]

Figure 4.15 ESI mass spectra for (A) angiotensin I and (B) bradykinin analyzed as a mixture (10 pM each) with a flow rate of 3pLmin 1, emitter-orifice distance of 10 mm and acquisition time of 0.5 s using an emitter prepared by the trimming method (P indicates PDMS background signal of 223 and 245 m/z). (Reprinted with permission from ref. 21). Figure 4.15 ESI mass spectra for (A) angiotensin I and (B) bradykinin analyzed as a mixture (10 pM each) with a flow rate of 3pLmin 1, emitter-orifice distance of 10 mm and acquisition time of 0.5 s using an emitter prepared by the trimming method (P indicates PDMS background signal of 223 and 245 m/z). (Reprinted with permission from ref. 21).
Figure 4.18 Signal stabilities obtained from PDMS emitter by the trimming method (A) TIC of PDMS background signal when using a solution of 1 1 methanol-water containing 0.1% acetic acid (B) TIC of the sample concentration of 1 pM peptide mixture (C) TIC of lOpM peptide mixture solution. The mass range of all TICs was between 200 and 700 m/z using a flow rate of 3 pLmuC1 with an emitter-orifice distance of 10 mm. (Reprinted with permission from ref. 21). Figure 4.18 Signal stabilities obtained from PDMS emitter by the trimming method (A) TIC of PDMS background signal when using a solution of 1 1 methanol-water containing 0.1% acetic acid (B) TIC of the sample concentration of 1 pM peptide mixture (C) TIC of lOpM peptide mixture solution. The mass range of all TICs was between 200 and 700 m/z using a flow rate of 3 pLmuC1 with an emitter-orifice distance of 10 mm. (Reprinted with permission from ref. 21).
Although a more sharply pointed emitter tip was expected to yield better electrospray performance, no difference was observed between point angles of 30 ° and 60 (Figure 4.7) for PDMS emitters prepared by the trimming method. However, the 60 ° angle was found to be preferable for tips prepared by other... [Pg.93]

The resistor performance like long-time stability or TCR does not depend only on the pulse voltage. The energy of the pulses must be carefully selected. Pulses with appropriate energy can act as an aging process. HVP-trimmed resistors often exhibit a better stability and TCR compared to untrimmed ones. Advantages and applications of EHVP trimming method are ... [Pg.397]

Let us give a few examples of how conformational transition states may be determined in an automated manner. The calculations have been carried out with HERMIT-SIRIUS-ABACUS [31, 32, 33] at the self-consistent field level using a minimal basis set. A simple example is provided by PH5, whose equilibrium structure is a trigonal bipyramid of D h symmetry. Starting at equilibrium and applying the TRIM method without symmetry constraints, we arrive after nine iterations at a square pyramidal transition state of C4V symmetry. This structure represents the barrier to a Berry pseudo-rotation connecting two equivalent Dsh equilibrium structures, as confirmed by walking down the other side of the barrier. [Pg.133]

For a more complicated case, consider the structure of cyclohexane, which exists in two conformational mimima, the chair structure of D d symmetry and the twist-boat structure of D2 symmetry. The chair conformer is stabilized with respect to the twisted boat by about 25 kJ/mole in a minimal basis. Starting at the D d equilibrium structure, the TRIM method reaches a first-order saddle point of C2 symmetry in 16 iterations and one backstep, again with no symmetry constraints applied. The activation energy is 49 kJ/mole. Minimizing from this structure, we reach the D2 twist-boat conformation in 10 second-order iterations. Thus we have been able to walk between the two stable conformers of cyclohexane in an automated manner. The uphill and downhill walks both require only a modest number of iterations, considering that they started far away in the global region. [Pg.133]


See other pages where TRIM method is mentioned: [Pg.964]    [Pg.964]    [Pg.68]    [Pg.71]    [Pg.71]    [Pg.75]    [Pg.75]    [Pg.76]    [Pg.77]    [Pg.77]    [Pg.80]    [Pg.80]    [Pg.81]    [Pg.88]    [Pg.91]    [Pg.94]    [Pg.94]    [Pg.242]    [Pg.40]    [Pg.395]    [Pg.398]    [Pg.398]    [Pg.398]    [Pg.453]    [Pg.104]    [Pg.131]    [Pg.869]    [Pg.87]   
See also in sourсe #XX -- [ Pg.79 ]




SEARCH



Four-Channel PDMS Emitter Prepared by the Trimming Method

Pulse voltage-trimming method

Trimming

Trimming method

Trimming methods, comparison

Trims

© 2024 chempedia.info