Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Titanium complexes optical resolution

Optically active diisopinocamphenylborane can be used to resolve racemic olefins. The reagent adds to one enantiomer, and the other is unchanged. Optical purities on the order of 37-65% are possible. Chiral ally lie alcohols can be resolved with chiral epoxidizing agents derived from tartrate complexes of titanium. One enantiomer is epoxidized and the other is not. Thus, die two alcohol enantiomers can be separated, one as the unsaturated alcohol and one as the epoxy alcohol. Use of die other tartrate isomer reverses die stereoselectivity. Selectivities on die order of >100 are possible with this method. As in any kinetic resolution, however, only one enantiomer can be recovered. The other is converted to a different chiral product. [Pg.143]

Transient terahertz spectroscopy Time-resolved terahertz (THz) spectroscopy (TRTS) has been used to measure the transient photoconductivity of injected electrons in dye-sensitised titanium oxide with subpicosecond time resolution (Beard et al, 2002 Turner et al, 2002). Terahertz probes cover the far-infrared (10-600 cm or 0.3-20 THz) region of the spectrum and measure frequency-dependent photoconductivity. The sample is excited by an ultrafast optical pulse to initiate electron injection and subsequently probed with a THz pulse. In many THz detection schemes, the time-dependent electric field 6 f) of the THz probe pulse is measured by free-space electro-optic sampling (Beard et al, 2002). Both the amplitude and the phase of the electric field can be determined, from which the complex conductivity of the injected electrons can be obtained. Fitting the complex conductivity allows the determination of carrier concentration and mobility. The time evolution of these quantities can be determined by varying the delay time between the optical pump and THz probe pulses. The advantage of this technique is that it provides detailed information on the dynamics of the injected electrons in the semiconductor and complements the time-resolved fluorescence and transient absorption techniques, which often focus on the dynamics of the adsorbates. A similar technique, time-resolved microwave conductivity, has been used to study injection kinetics in dye-sensitised nanocrystalline thin films (Fessenden and Kamat, 1995). However, its time resolution is limited to longer than 1 ns. [Pg.643]


See other pages where Titanium complexes optical resolution is mentioned: [Pg.479]    [Pg.50]    [Pg.483]    [Pg.483]    [Pg.338]    [Pg.949]    [Pg.676]    [Pg.265]    [Pg.263]    [Pg.479]    [Pg.408]    [Pg.286]    [Pg.63]    [Pg.56]   
See also in sourсe #XX -- [ Pg.158 ]




SEARCH



Optical resolution

Titanium complexe

Titanium complexes

© 2024 chempedia.info