Test Method Stipulated in the Japanese Fire Services Law A

2 Test method stipulated in the Japanese Fire Services Law (A ) [Pg.79]

The purpose of this test is to evaluate the explosiveness of solid or liquid substances. For this purpose,measurements are made of the exothermic characteristics due to self-reactivity, such as the decomposition reaction induced in association with a rise in test article temperature. [Pg.79]

Use a differential scanning colorimeter (DSC) or differential thermal analysis (DTA) apparatus 1 with aluminium oxide ( a - alumina) as the reference substance. [Pg.79]

Set the hermetically sealed pressure cell 2 j containing a standard substance (lmg of DNT or 2mg of BPO) on the test apparatus, and heat at a rate of 10 0 C/min. Determine the exothermic start temperature and calorific value on the recording chart 4. Perform the test five times, and determine the average of the five runs. [Pg.79]

Same as (a) above except that the amount of sample is about 2mg (but modified according to the calorific value). [Pg.79]