Steady-flow devices

Heat exchangers operate for long periods with no change in the operating conditions thus, they can be modelled as steady-flow devices, for which the following assumptions are valid ... [Pg.117]

Many devices such as turbines, compressors, boilers, condensers, and heat exchangers operate for long periods of time under the same conditions, and they are classified as steady flow devices. (Note that the flow field near the rotating blades of a turbomachine is of course unsteady, but we consider the overall flow field rather tlian the details at some localities when we classify device.s.) During steady flow, the fluid properties can change from point to point within a device, but at any fixed point they remain constant. Therefore, the volume, the mass, and the total energy content of a steady-flow device or flow section remain constant in steady operation. [Pg.380]

The ex pans ion-type CPC is cyclic in operation, and this may pose a problem in measuring concentrations from steady flow devices such as the electrical mobility analyzer and diffusion battery discussed later. Continuous-(low CPCs have been developed in... [Pg.163]

An engineer claims to have invented a steady-flow device that will take air at 4 bar and 20"C and separate it into two streams of equal mass, one at 1 bar and —20 C and the second at 1 bar and 60°C. Furthermore, the inventor states that his device operates adiabatically and does not require (or produce) work. Is such a device possible (Air can be assumed to be an ideal gas with a constant heat capacity of Cp = 29.3 J/(mol K)]. [Pg.135]

With the steady flow device it is possible to evaluate some fluidodynamic characteristics of prosthetic valves. One of these is the systolic transvalvular pressure gradient which gives a comparative evaluation between different kinds of prostheses. Regarding the aortic valve as a hydraulic concentrated resistance, the equation of Darcy ... [Pg.342]

The behaviour of the fluid around the valve can be studied using the steady flow device for the visualization of the flow patterns. With the steady flow device only the behaviour in condition of systolic peak is observable, but it is already a good indication. A pulsatile pump for the visualization of the flow patterns in pulsatile flow condition is being designed. [Pg.344]

The term (m + Fv ToS) becomes (m + Fv — Ts) for this isothermal process. If we further restrict our attention to a steady flow device with only one flow in and out, this further simplifies to... [Pg.30]

What is the minimum reversible power needed to separate this solution into pure species in an isothermal steady-flow device Express your answer inBtu/Ibmol. [Pg.140]

Steady flow devices that employ seals within the blood stream deserve very careful consideration of the seal area. These seals have been prone to failure causing embolization. Both actively and passively suspended devices have been designed. A device that utilizes a rotating member, such as a rotating electric motor that would drive an impeller or mechanical mechanism, will create forces on the tissue when the patient moves due to gyroscopic or Coriolis accelerations, these forces must be considered. [Pg.1516]

The heat supply to the cyclic gas turbine power plant of Fig. 1.2 comes from the control surface Z. Within this second control surface, a steady-flow heating device is supplied with reactants (fuel and air) and it discharges the products of combustion. We may define a second efficiency for the heating device (or boiler) efficiency. [Pg.5]

Continuous flow devices have undergone careful development, and mixing chambers are very efficient. Mixing is essentially complete in about 1 ms, and half-lives as short as 1 ms may be measured. An interesting advantage of the continuous flow method, less important now than earlier, is that the analytical method need not have a fast response, since the concentrations are at steady state. Of course, the slower the detection method, the greater the volumes of reactant solutions that will be consumed. In 1923 several liters of solution were required, but now reactions can be studied with 10-100 mL. [Pg.178]

Pumps are devices for supplying energy or head to a flowing liquid in order to overcome head losses due to friction and also, if necessary, to raise the liquid to a higher level. The head imparted to a flowing liquid by a pump is known as the total head Ah. If a pump is placed between points 1 and 2 in a pipeline, the heads for steady flow are related by equation 1.14... [Pg.140]

The experimental strategy in studying catalytic kinetics usually involves measuring the extent of conversion of gas passing in steady flow through a batch of solids. Any flow pattern can be used, as long as the pattern selected is known if it is not known then the kinetics cannot be found. A batch reactor can also be used. In turn we discuss the following experimental devices ... [Pg.396]

The steady flow rate observed in the heparin infusion study with the corresponding delay in clotting time indicates that the infusion device can provide dependable controlled release. Since the service life, size and flow rate of the device may be varied depending on the requirements of an experiment, these features should make it readily adaptable to the infusion of many other drugs. [Pg.350]

Crude oil and brine pumps may be centrifugal or positive displacement, but must be capable of providing steady flow to the mixing device because emulsion properties are highly dependent on the resulting crude-oil-brine ratio. Surfactant may be dissolved in the brine phase on a batch or continuous basis. Static mixers provide a simple method for the preparation step because they require no moving parts, are easy to scale up, and provide an mixing intensity that is suited to preparation of transport emulsions. [Pg.299]

ASTM C 522 covers the measurement of airflow resistance and the related measurements of specific airflow resistance and airflow resistivity of porous materials that can be used for the absorption and attenuation of sound. The method describes how to measure a steady flow of air through a test specimen, how to measure the air-pressure difference across the specimen, and how to measure the volume velocity of airflow through the specimen. The airflow resistance, R, the specific airflow resistance, r, and the airflow resistivity, rQ, may be calculated from the measurements. The apparatus includes a suction generator or positive air supply arranged to draw or force air at a uniform rate through the specimen. A flowmeter is used to measure the volume velocity of airflow through the specimen, and a differential-pressure-measuring device measures the static-pressure difference between the two faces of the specimen with respect to atmosphere. [Pg.372]

On the other hand, passive chaotic micromixers typically use complex three-dimensional twisted conduits fabricated in various substrates such as silicon [13], polydimethylsiloxane (PDMS) [14], ceramic tape [15], or glass [13] to create 3-D steady flow velocity with a certain complexity to achieve chaotic advection. T q)ical examples of the aforementioned two routes to achieve chaotic advection and mixing in LOC devices are presented in the following. [Pg.259]

Joe Unidel claims to have invented a steady-state flow device in which the inlet is steam at 300 C and 5 bar. the outlet is saturated steam at 100°C and I bar, the device is adiabatic and produces approximately 388 kJ per kilogram of steam passed through the device. Should we believe his claim ... [Pg.141]

Diodes have several important applications in electronics. The power supplied by most electrical utilities is typically alternating current (AC) that is, the direction of current flow switches back and forth with a frequency of sixty cycles per second. However, many electronic devices reqnire a steady flow of current in one direction (direct current or DC). Since a diode only allows current to flow through it in one direction, it can be combined with a capacitor to convert AC input to DC output. For half the AC cycle, the diode passes current and the capacitor is charged up. During the other half of the cycle, the diode blocks any cnrrent from the fine, but current is provided to the circuit by the capacitor. Diodes appfied in this way are referred to as rectifiers. [Pg.1144]


See other pages where Steady-flow devices is mentioned: [Pg.149]    [Pg.154]    [Pg.171]    [Pg.636]    [Pg.333]    [Pg.341]    [Pg.342]    [Pg.149]    [Pg.154]    [Pg.171]    [Pg.636]    [Pg.333]    [Pg.341]    [Pg.342]    [Pg.8]    [Pg.227]    [Pg.380]    [Pg.253]    [Pg.94]    [Pg.299]    [Pg.293]    [Pg.342]    [Pg.10]    [Pg.414]    [Pg.326]    [Pg.377]    [Pg.32]    [Pg.380]    [Pg.137]    [Pg.382]    [Pg.126]    [Pg.144]    [Pg.340]    [Pg.318]    [Pg.443]    [Pg.212]   