SPM system

Different SPM systems were developed to study the thermal properties. Thus a tiny thermocouple can be used to measure the heat flow from the surface and to test the local thermo conductivity of polymer surfaces [161]. Recently, a bimetallic cantilever has been used as temperature sensor to investigate phase transitions of n-alkanes with a heat sensitivity of 500 pj for a sample mass as low as to... [Pg.90]

An SPM system consists of several basic components probe and its motion sensor, scanner, electric controller, computer and vibration isolation system as schematically shown in Figure 5.1. These components are briefly introduced in the following sections. [Pg.146]

Quesant Instrument Co., 29397 Agoura Road, Suite 104, Agoura Hills, CA 91301, 818-597-0311 (http //www.quesant.com). Inexpensive SPM systems. [Pg.69]

Further, as the er ergy of the spm system for times T stays the same, we receive... [Pg.185]

Some of these SPM systems can be combined with others - a conducting tip on a cantilever can be operated as a combined STM and AFM. Measurement of both vertical and lateral forces gives a FFM and AFM. Tunneling from a thermocouple tip gives STM and STP, and the combined effect measures local chemical potential [86]. [Pg.35]

Figure 1. Schematic representation of the essential elements and the image formation process of the SPM system. Figure 1. Schematic representation of the essential elements and the image formation process of the SPM system.
The following will constitute a brief, and necessarily incomplete, account of the essential underlying physical principles which account for the information content of the SPM system. The discussion will be limited to STM/STS and to AFM and its variants. [Pg.402]

A block diagram of an SPM system is. shown in Fig. 8. The tip" and sample" elements of the total system are at the heart of SPM and will be dealt with under separate headings. Until about 1987. SPM instruments were constructed in-house. Some in-house design and construction is still taking place, but the overwhelming... [Pg.410]

Topographic image was collected by Multimode AFM (NanoScope pa SPM system,Americ DI/ Veeco,Inc,Santa Barbara CA) equipped with a J scanner. A triangle cantilever spring constant of 48 N/m (Mikromasch) was used. The sample was then observed by tapping mode AFM in air with relative humidity of 20% 30% at 20 25. [Pg.1484]

Fig. 2. Illustrations of the distinctiveness of the state of a locus whose gene is under the control of the Spm system. All kernels on the right-hand ear have one state and all on the left-hand ear have another. The variegated kernels on each ear have a fully active Spm element whereas the uniformly pale-pigmented kernels la< k this element. Fig. 2. Illustrations of the distinctiveness of the state of a locus whose gene is under the control of the Spm system. All kernels on the right-hand ear have one state and all on the left-hand ear have another. The variegated kernels on each ear have a fully active Spm element whereas the uniformly pale-pigmented kernels la< k this element.

See other pages where SPM system is mentioned: [Pg.1507]    [Pg.2105]    [Pg.568]    [Pg.168]    [Pg.1520]    [Pg.362]    [Pg.364]    [Pg.27]    [Pg.177]    [Pg.540]    [Pg.583]    [Pg.139]    [Pg.140]    [Pg.117]    [Pg.397]    [Pg.398]    [Pg.411]    [Pg.91]    [Pg.96]    [Pg.104]    [Pg.105]    [Pg.106]   