Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Signal matching

Uses For tracer powder and red-colored flares. In combination with barium nitrate it is used in aviation for signaling and for illuminating landing fields and military objectives. In marine signals, matches, and railroad flares. [Pg.141]

A different approach to signal matching is to calibrate each detector independently. Because each detector is calibrated independently, the signals can be matched through the corresponding calibration curves alone, eliminating the need for offsets. [Pg.80]

Figure 5. Schematic of the method of signal matching for independently calibrated detectors (see text). Figure 5. Schematic of the method of signal matching for independently calibrated detectors (see text).
The Approximate signal matching method for Inorganic IDMS 19... [Pg.10]

Corrections need to be made for instrumental effects, such as mass bias and detector dead-time (see Section 3.10). Using the signal matching procedures outlined in this guide this can be achieved by running an alternating sequence of standards and samples. [Pg.14]

Figure 1 Schematic representation of the exact signal matching IDMS procedure, as applied to organic analysis... Figure 1 Schematic representation of the exact signal matching IDMS procedure, as applied to organic analysis...
The Exact signal matching Method for Organic IDMS... [Pg.27]

IDMS analysis of the sample blend was then carried out using replicate measurements as described for the exact signal matching technique. Five replicate measurements were carried out using ions with m/z of 318 and 330. The mean ion abundance ratio of the sample blend ( ) was 0.98803 and that of the reference standard blend 0.95462. Equation 11 (Annex 3) produced a result (cx) for the first iteration of 3.944 figg of / ,/ -DDE in the sample solution. [Pg.28]

The greatest accuracy attainable by MS is achieved by Isotope Dilution Mass Spectrometry using an exact signal matching method. Like other SIM techniques, an isotopically labeled internal standard is added gravimetrically to the analyte, prior to extraction from its matrix. The quantity of internal standard is then adjusted, over a number of iterations, such that the signal obtained exactly matches that of... [Pg.2869]

Middendorp P, Raiding FJ (1988) Determination of discontinnities in piles by TNO integrity testing and signal matching teclmiqnes. Proc of the 3 International Conference of the Application of Stress-Wave Theory to Piles, pp 33-43... [Pg.364]


See other pages where Signal matching is mentioned: [Pg.348]    [Pg.159]    [Pg.85]    [Pg.151]    [Pg.6313]    [Pg.79]    [Pg.79]    [Pg.80]    [Pg.158]    [Pg.6312]    [Pg.10]    [Pg.20]    [Pg.21]    [Pg.21]    [Pg.22]    [Pg.22]    [Pg.29]    [Pg.29]    [Pg.38]    [Pg.59]    [Pg.288]    [Pg.572]    [Pg.169]    [Pg.420]    [Pg.1048]    [Pg.291]    [Pg.30]   


SEARCH