Sieve trays static packed columns

The selection criteria listed in Section 13.1 indicate that mixer-setders are a good choice if only a few equilibrium stages are needed however, if, as is often the case, a few more stages are required, then a nonagitated (static) column such as a spray, sieve tray, or packed column should be used. These columns are commonly used for relatively large-scale systems in the chemical and petrochemical industries. [Pg.563]

The static packed column, shown in Fig. 6.3-1, is more efficient with respect to mass transfer. Its design is similar to that of gas/hquid systems (e.g., absorption and distillation). In contrast, the design of a static tray column, used for solvent extraction, is completely different from the corresponding column for gas/liquid service. The sieve trays have very small hole diameters (2-4 mm) and a very small free area 2-4%) (Fig. 6.3-1). [Pg.362]

Figure 12.16 Illustration of possible types of slurry bubble column reactors, (a) Simple bubble column, (b) cascade bubble column with sieve trays, (c) packed bubble column, (d) multishaft bubble column, and (e) bubble column with static mixers [61]. Figure 12.16 Illustration of possible types of slurry bubble column reactors, (a) Simple bubble column, (b) cascade bubble column with sieve trays, (c) packed bubble column, (d) multishaft bubble column, and (e) bubble column with static mixers [61].
Static extraction columns Spray column Baffle column Packed column (random and structured packing) Sieve tray column Deliver low to medium mass-transfer efficiency, simple construction (no internal moving parts), low capital cost, low operating and maintenance costs, best suited to systems with low to moderate interfacial tension, can handle high production rates Petrochemical Chemical Food... [Pg.1745]

FIG. 15-32 Schematic of common static extractors, (a) Spray coiumn. ib) Packed column, (c) Sieve tray column. [Pg.1750]

Fig. 6.3-4 Typical performance data of ten different extractor designs for the system tolulene/acetone/water. MS mixer-settler, SE static sieve tray column, PC static packed packed column, RDC rotating disc contactor, PSE pulsed sieve tray column, PPC pulsed packed column, RZE agitated cell extractors... Fig. 6.3-4 Typical performance data of ten different extractor designs for the system tolulene/acetone/water. MS mixer-settler, SE static sieve tray column, PC static packed packed column, RDC rotating disc contactor, PSE pulsed sieve tray column, PPC pulsed packed column, RZE agitated cell extractors...
Figure 7.1 Conventional equipment used for fluid-fluid reactions (columns (a) multistage agitated column, (b) packed column, (c) sieve tray column, (d) buss loop reactor, (e) tubular reactor, and (f) static mixer)... Figure 7.1 Conventional equipment used for fluid-fluid reactions (columns (a) multistage agitated column, (b) packed column, (c) sieve tray column, (d) buss loop reactor, (e) tubular reactor, and (f) static mixer)...

See other pages where Sieve trays static packed columns is mentioned: [Pg.53]    [Pg.142]   
See also in sourсe #XX -- [ Pg.361 , Pg.362 ]




SEARCH



Columns sieve trays

Columns static sieve tray

Packed columns

Packed columns, packing

Sieve trays

Static column