Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Scanning distance

D > 10" cm Hz W ) generally operate best in the mid-IR region. The resulting interferogram is a function of the intensity versus the distance, v of MM. This scan distance, v determines the spectral resolution A/z ... [Pg.620]

Fig. 4.13 Friction loop (friction signal [V] vs. scanned distance [nm] plot) measured perpendicular to the polymer chain direction of oriented polyethylene with a -CF3 modified tip. [31]... Fig. 4.13 Friction loop (friction signal [V] vs. scanned distance [nm] plot) measured perpendicular to the polymer chain direction of oriented polyethylene with a -CF3 modified tip. [31]...
Two modes of operation of the apparatus are possible (1) The scanning mode in which the sample surface reflectance can be recorded as a function of scanning distance at ambient room temperature or at elevated temperatures and (2) the change in reflectance of the sample as a function o f temperature can be recorded. The former mode is called high-temperature scanning micro-reflectance SMR), while the latter is called dynamic microreflectance (DMR). The use of these two modes is illustrated by the deaquation of CuS0d-5H20. [Pg.594]

Such imaging efforts are important because they prove that SECM may be used to pattern enzymes (Figure 12.32), optimize enzyme architectures, and characterize miniaturized multi-sensor arrays. Patterning of enzymes on surfaces and the long scanning distances of SECM make this an attractive option for enzyme activity assays. In order for them to be used to extract enzyme kinetics, however, a significant amount of work remains to be done. [Pg.528]

Optimized B3LYP/3-21G energies ( ,) for the Diels-Alder Potential Scan at combined scan distances (in bohr) from 6.50 to 10.00 in steps of 0.25... [Pg.326]

The scan distance, the increment distance, and increment time (sampling time) can be specified. The probe scan can be aborted manually if the current is either greater or less than a specified level, for probe protection. [Pg.21]

Focus position of laser spot 2 mm below from the surface Laser scanning distance 18 mm (straight line)... [Pg.400]


See other pages where Scanning distance is mentioned: [Pg.230]    [Pg.232]    [Pg.497]    [Pg.272]    [Pg.68]    [Pg.56]    [Pg.52]    [Pg.226]    [Pg.91]    [Pg.100]    [Pg.90]    [Pg.122]    [Pg.411]    [Pg.239]    [Pg.296]    [Pg.22]    [Pg.441]    [Pg.893]   
See also in sourсe #XX -- [ Pg.102 ]




SEARCH



© 2024 chempedia.info