Rotor balancing imbalance causes

If the operator removes the rotor from the balancing shaft without marking the point of bore and shaft contact, it may not be in the same position when reassembled. This often shifts the rotor by several mils as compared to the axis on which it was balanced, thus causing an imbalance to be introduced. The vibrations that result are usually enough to spoil what should have been a precision balance and produce a barely acceptable vibration level. In addition, if the resultant vibration is resonant with some part of the machine or structure, a more serious vibration could result. [Pg.936]

Make sure that the outside of the centrifuge tubes, the sample holders and sample chambers are dry any liquid present will cause an imbalance during centrifugation (as well as potentially causing corrosive damage to the rotor). Balanced tubes must be placed opposite each other, use a simple code if necessary, to prevent errors. [Pg.137]

Mechanical imbalance is one of the most common causes of machinery vibration and is present to some degree on nearly all machines that have rotating parts or rotors. Static, or standing, imbalance is the condition when there is more weight on one side of a centerline than the other. However, a rotor may be in perfect static balance and not be in a balanced state when rotating at high speed. [Pg.936]

Shifting any rotor from the rotational center on which it was balanced to the piece of machinery on which it is intended to operate can cause an assembly imbalance four to five times greater than that resulting simply from tolerances. For this reason, all rotors should be balanced on a shaft having a diameter as nearly the same as the shaft on which it will be assembled. [Pg.936]

Imbalance often results with rotors that do not incorporate setscrews to locate the shaft relative to the bore (e.g., rotors that are end clamped). In this case, the balancing shaft is usually horizontal. When the operator slides the rotor on the shaft, gravity causes the rotor s bore to make contact at the 12 o clock position on the top surface of the shaft. In this position, the rotor is end-clamped in place and then balanced. [Pg.936]

Although the definition of dynamic imbalance covers all two-plane situations, an understanding of the components of dynamic imbalance is needed so that its causes can be understood. Also, an understanding of the components makes it easier to understand why certain types of balancing do not always work with many older balancing machines for overhung rotors and very narrow rotors. The primary components of dynamic imbalance include number of points of imbalance, amount of imbalance, phase relationships, and rotor speed. [Pg.938]

Couple imbalance is caused by two equal non-colinear imbalance forces that oppose each other angularly (i.e., 180° apart). Assume that a rotor with pure couple imbalance is placed on frictionless rollers. Because the imbalance weights or forces are 180° apart and equal, the rotor is statically balanced. However, a pure couple imbalance... [Pg.938]


See other pages where Rotor balancing imbalance causes is mentioned: [Pg.669]    [Pg.936]    [Pg.59]    [Pg.102]   