Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Rotating-disc contactor-RDC

K. Liquid-liquid extraction in Rotating-disc contactor (RDC)... [Pg.623]

For example, to calculate the dispersion coefficient for a Rotating Disc Contactor (RDC), given in [6.24],... [Pg.418]

Usually, practical design correlations for and or the characteristic velocity v are directly derived from experimental data. For example, in an Rotating Disc Contactor (RDC), in the operating range of interest, the velocity limit of the dispersed phase at the flooding point is according to Strobel and Salzer [6.30]... [Pg.420]

Fig. 6-44. Torque as the Newton number, Ne of one cell as a function of the Reynolds number Re for a rotating disc contactor RDC. Representation according to Husung [6.69]. Fig. 6-44. Torque as the Newton number, Ne of one cell as a function of the Reynolds number Re for a rotating disc contactor RDC. Representation according to Husung [6.69].
There are three wo well known types of column that can be used for continuous countercurrent liquid/liquid contacting rotating disc contactors (RDC) and pulsed packed columns (PPC) (these are not to be confused with three-phase packed coplumn reactors, operated under pulsed flow conditions, see section 4.7.2.3). [Pg.115]

Code AC (Agitated CeU) - PTC (Pulsed Packed Cdumn) - PST (Pulsed Sieve Tray) - RDC (Rotating-Disc Contactor - PC (Pecked Column) - MS (Mixer Settler) - ST (Sieve Tray)... [Pg.356]

RDC Column. The rotating disc contactor (Fig. 19) provides for redispersion by a series of discs along the shaft, combined with a series of fixed stators. Vortices are formed in each compartment, and the shear of the fluid against the rotor or stator causes the drop breakup. In many instances. [Pg.368]

Fig. 6.3-4 Typical performance data of ten different extractor designs for the system tolulene/acetone/water. MS mixer-settler, SE static sieve tray column, PC static packed packed column, RDC rotating disc contactor, PSE pulsed sieve tray column, PPC pulsed packed column, RZE agitated cell extractors... Fig. 6.3-4 Typical performance data of ten different extractor designs for the system tolulene/acetone/water. MS mixer-settler, SE static sieve tray column, PC static packed packed column, RDC rotating disc contactor, PSE pulsed sieve tray column, PPC pulsed packed column, RZE agitated cell extractors...

See other pages where Rotating-disc contactor-RDC is mentioned: [Pg.385]    [Pg.330]    [Pg.289]    [Pg.296]    [Pg.369]    [Pg.271]    [Pg.363]    [Pg.927]    [Pg.426]    [Pg.441]    [Pg.446]    [Pg.385]    [Pg.330]    [Pg.289]    [Pg.296]    [Pg.369]    [Pg.271]    [Pg.363]    [Pg.927]    [Pg.426]    [Pg.441]    [Pg.446]    [Pg.337]    [Pg.1745]    [Pg.1748]    [Pg.59]    [Pg.62]    [Pg.1739]    [Pg.1742]    [Pg.54]    [Pg.43]   
See also in sourсe #XX -- [ Pg.314 ]