Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Refocusing

The resolution eidiancenient stems from the fact that the qiiadnipole frequencies for both transitions are correlated. At specific times the anisotropic parts of the qiiadnipole interaction are refocused and an echo fonns. The frequency of an (m, -m) transition is given by... [Pg.1488]

Figure Bl.14.1. Spin warp spin-echo imaging pulse sequence. A spin echo is refocused by a non-selective 180° pulse. A slice is selected perpendicular to the z-direction. To frequency-encode the v-coordinate the echo SE is acquired in the presence of the readout gradient. Phase-encoding of the > -dimension is achieved by incrementmg the gradient pulse G... Figure Bl.14.1. Spin warp spin-echo imaging pulse sequence. A spin echo is refocused by a non-selective 180° pulse. A slice is selected perpendicular to the z-direction. To frequency-encode the v-coordinate the echo SE is acquired in the presence of the readout gradient. Phase-encoding of the > -dimension is achieved by incrementmg the gradient pulse G...
Figure Bl.14.2. Gradient-recalled echo pulse sequence. The echo is generated by deliberately dephasing and refocusing transverse magnetization with the readout gradient. A slice is selected in the z-direction and v- and y-dimension are frequency and phase encoded, respectively. Figure Bl.14.2. Gradient-recalled echo pulse sequence. The echo is generated by deliberately dephasing and refocusing transverse magnetization with the readout gradient. A slice is selected in the z-direction and v- and y-dimension are frequency and phase encoded, respectively.
In electron-spin-echo-detected EPR spectroscopy, spectral infomiation may, in principle, be obtained from a Fourier transfomiation of the second half of the echo shape, since it represents the FID of the refocused magnetizations, however, now recorded with much reduced deadtime problems. For the inhomogeneously broadened EPR lines considered here, however, the FID and therefore also the spin echo, show little structure. For this reason, the amplitude of tire echo is used as the main source of infomiation in ESE experiments. Recording the intensity of the two-pulse or tliree-pulse echo amplitude as a function of the external magnetic field defines electron-spm-echo- (ESE-)... [Pg.1577]

These experiments yield T2 which, in the case of fast exchange, gives the ratio (Aoi) /k. However, since the experiments themselves have an implicit timescale, absolute rates can be obtained in favourable circumstances. For the CPMG experiment, the timescale is the repetition time of the refocusing pulse for the Tjp experiment, it is the rate of precession around the effective RF field. If this timescale is fast witli respect to the exchange rate, then the experiment effectively measures T2 in the absence of exchange. If the timescale is slow, the apparent T2 contains the effects of exchange. Therefore, the apparent T2 shows a dispersion as the... [Pg.2106]

The hexapole cannot act as a mass filter by applying a DC field and is used only in its all-RF mode, in which it allows all ions in a beam to pass through, whatever their m/z values. In doing so, the ion beam is constrained, so it leaves the hexapole as a narrow beam. This constraint is important because the ion beam from the inlet system tends to spread due to mutual ion repulsion and collision with residual air and solvent molecules. By injecting this divergent beam into a hexapole unit, it can be refocused. At the same time, vacuum pumps reduce the background pressure to about 10 mbar (Figure 22.1). The pressure needed in the TOF analyzer is about 10 ... [Pg.164]

X-rays are collected and analy2ed in ema in one of two ways. In wds, x-rays are dispersed by Bragg diffraction at a crystal and refocused onto a detector sitting on a Rowland circle. This arrangement is similar to the production of monochromati2ed x-rays for xps described above. In the other approach, edx, x-rays are all collected at the same time in a detector whose output scales with the energy of the x-ray (and hence, Z of the material which produces the x-ray.) Detectors used for ema today are almost exclusively Li-drifted Si soHd-state detectors. [Pg.285]

Societies concern with air quality has evolved from medieval times, when breathing smelting fumes was a major hazard, to where we are today (see Chapter 1). In modem society, a parallel effort has been under way to improve air quality in the outside or ambient air, which is the focus of this book, and in the industrial occupational setting in manufacturing and other traditional jobs. A combination of events is moving many countries to consider the quality of air in other locations where we live parts of our lives. Attention is now being refocused on "indoor" air quality. [Pg.382]

Figure 2.2 Schematic representation of an on-column interface. The eluent leaving the HPLC detector enters the valve and in the stand-hy position, leaves it to go to waste. When the valve is switched on, the eluent is pumped through the transfer line into the inlet of the on-column injector. The liquid floods the capillary wall, thus creating a layer that will retain the solutes. Evaporation occurs from the rear pait of the solvent so refocusing the chromatographic hand. At the end of the transfer, the valve is switched off, and the eluent again flows to waste. Figure 2.2 Schematic representation of an on-column interface. The eluent leaving the HPLC detector enters the valve and in the stand-hy position, leaves it to go to waste. When the valve is switched on, the eluent is pumped through the transfer line into the inlet of the on-column injector. The liquid floods the capillary wall, thus creating a layer that will retain the solutes. Evaporation occurs from the rear pait of the solvent so refocusing the chromatographic hand. At the end of the transfer, the valve is switched off, and the eluent again flows to waste.
The efficiency of the "D is partly a consequence of the zone refocusing mechanism, as depicted in Figure 8.7. Each time the solvent front traverses the stationary sample in multiple development it compresses the zone in the direction of development. The compression occurs because the mobile phase first contacts the bottom edge of the zone, where the sample molecules start to move forward before those... [Pg.178]

Figure 8.7 Schematic diagram of the zone refocusing mechanism (a) the applied sample before starting the separation (b) the solvent front reaches the first stage ( = 1), where the sample starts to refocus (c) the solvent front reaches the second stage (n = 2), where all compounds together start to migrate. Figure 8.7 Schematic diagram of the zone refocusing mechanism (a) the applied sample before starting the separation (b) the solvent front reaches the first stage ( = 1), where the sample starts to refocus (c) the solvent front reaches the second stage (n = 2), where all compounds together start to migrate.
The use of dynamic refocusing optics is currently being tested at the Stewart... [Pg.223]

Bodner, G. M. (1992). Refocusing the general chemistry curriculum. Journal of Chemical Education, 69, 186-190. [Pg.8]

Garnett, P. J., Garnett, P. J., Hackling, M. W. (1995). Refocusing the chemistry lab A case for laboratory-based investigations. Australian Science Teachers Journal, 41 (2), 26-32. [Pg.131]


See other pages where Refocusing is mentioned: [Pg.1496]    [Pg.1524]    [Pg.1525]    [Pg.1526]    [Pg.1527]    [Pg.1529]    [Pg.1541]    [Pg.1576]    [Pg.1579]    [Pg.1586]    [Pg.1986]    [Pg.2105]    [Pg.2816]    [Pg.292]    [Pg.233]    [Pg.115]    [Pg.198]    [Pg.600]    [Pg.7]    [Pg.52]    [Pg.55]    [Pg.57]    [Pg.63]    [Pg.69]    [Pg.179]    [Pg.165]    [Pg.1052]    [Pg.1149]    [Pg.428]    [Pg.48]    [Pg.75]    [Pg.84]    [Pg.114]    [Pg.223]    [Pg.223]    [Pg.90]   
See also in sourсe #XX -- [ Pg.227 , Pg.248 , Pg.251 , Pg.271 , Pg.284 , Pg.304 , Pg.504 ]

See also in sourсe #XX -- [ Pg.90 ]

See also in sourсe #XX -- [ Pg.143 , Pg.147 , Pg.149 , Pg.174 ]

See also in sourсe #XX -- [ Pg.103 ]

See also in sourсe #XX -- [ Pg.27 , Pg.155 ]




SEARCH



Chemical shift refocusing

Decoupled refocused INEPT

Focusing-Refocusing Events

Gradient-selected refocused INEPT

INEPT refocused

REfocused INADEQUATE spin-Echo

Refocused INEPT Adding Spectral Editing

Refocused INEPT sequence

Refocused INEPT technique

Refocused echo

Refocusing delay

Refocusing pulse

Refocusing similar

Self-refocusing pulses

Spin Refocusing

© 2024 chempedia.info