The statement that the mass, or weight flow of vapor through the trays, increases as the refluxed rate is raised is based on the reboiler being on automatic temperature control. If the reboiler were on manual control, then the flow of steam and the reboiler heat duty would remain constant as the reflux rate was increased, and the weight flow of vapor up the tower would remain constant as the top reflux rate was increased. But the liquid level in the reflux drum would begin to drop. The reflux drum level recorder controller (LRC) would close off to catch to falling level, and the overhead product rate would drop, in proportion to the increase in reflux rate. We can now draw some conclusions from the foregoing discussion ... [Pg.37]