Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Redundancy partial

The calculation of characteristic values causes a high amount of values which contain redundant informations. Due to this the forth partial step will be to reduce this amount of values using extraction methods. This can be realized with statistical methods like cross correlation analysis. [Pg.16]

A potentially general method of identifying a probe is, first, to purify a protein of interest by chromatography (qv) or electrophoresis. Then a partial amino acid sequence of the protein is deterrnined chemically (see Amino acids). The amino acid sequence is used to predict likely short DNA sequences which direct the synthesis of the protein sequence. Because the genetic code uses redundant codons to direct the synthesis of some amino acids, the predicted probe is unlikely to be unique. The least redundant sequence of 25—30 nucleotides is synthesized chemically as a mixture. The mixed probe is used to screen the Hbrary and the identified clones further screened, either with another probe reverse-translated from the known amino acid sequence or by directly sequencing the clones. Whereas not all recombinant clones encode the protein of interest, reiterative screening allows identification of the correct DNA recombinant. [Pg.231]

From the definition of a partial molar quantity and some thermodynamic substitutions involving exact differentials, it is possible to derive the simple, yet powerful, Duhem data testing relation (2,3,18). Stated in words, the Duhem equation is a mole-fraction-weighted summation of the partial derivatives of a set of partial molar quantities, with respect to the composition of one of the components (2,3). For example, in an / -component system, there are n partial molar quantities, Af, representing any extensive molar property. At a specified temperature and pressure, only n — 1) of these properties are independent. Many experiments, however, measure quantities for every chemical in a multicomponent system. It is this redundance in reported data that makes thermodynamic consistency tests possible. [Pg.236]

The well-known Gibbs-Duhem equation (2,3,18) is a special mathematical redundance test which is expressed in terms of the chemical potential (3,18). The general Duhem test procedure can be appHed to any set of partial molar quantities. It is also possible to perform an overall consistency test over a composition range with the integrated form of the Duhem equation (2). [Pg.236]

Hazards that could lead to injury of company personnel. Partial redundancy is often required (For example, redundant measurements but not redundant logic). [Pg.797]

Heber, S., Herms, J., Gajic, V. et al. Mice with combined gene knock-outs reveal essential and partially redundant functions of amyloid precursor protein family members. J Neurosci. 20 7951-7963,2000. [Pg.789]

For each redundancy, a belief is then defined on a two-dimensional state-universe. When dealing with the AD process previously presented, this relation is used for volatile fatty acids, total and partial alkalinity provided by the titrimetric sensor and the FT-IR spectrometer. [Pg.221]

Santisteban, M.S., Kalashnikova, T., and Smith, M.M. (2000) Histone H2A.Z regulates transcription and is partially redundant with nucleosome remodeling complexes. Cell 103, 411 22. [Pg.200]

ISWla Iswlp S. cerevisiae Ioc3p Partial redundancy with CHDl, ISW2 and ISWlb [94,96]. Iswl functions in the repression of transcription following recruitment to promoters by Cbfl [289], it is not known which ISWI complexes are involved. [Pg.425]

ISWlb Iswlp S. cerevisiae Ioc2p-Ioc4p Partial redundancy with CHDl, ISW2 and ISWla [94,96. ... [Pg.425]

ISW2 Isw2p S. cerevisiae Itclp (pl40) Partial redundancy with CHDl and ISWI [94]. Repression of early meiotic genes in parallel with the Sin3-Rpd3 histone deacetylase complex [235,236]. [Pg.425]

S. cerevisiae 1000 molecules/cell. Chdlp is partially redundant with SWI/SNF complex, ISWlp and ISW2p [94,98]. Chdlp may function during transcript elongation [255]. [Pg.426]

Several units with a PM collection device located upstream of the SCR have seen increased pressure drop from fine particulates accumulating on the catalyst bed. Soot blowers have been partially successful in this application. When the SCR is applied to a CO boiler with limited pressure drop, the SCR has typically been located upstream of PM removal to avoid this problem. Some refiners have chosen to install a spare SCR reactor to provide redundancy due to pressure drop concerns. Others have used a bypass where local regulations allow. [Pg.330]

A third point of resemblance between detergency and flotation (perhaps redundant in view of what has already been said) is that both have developed largely by empirical research with (partially satisfactory) explanations trailing far behind the actual practice. [Pg.339]


See other pages where Redundancy partial is mentioned: [Pg.251]    [Pg.251]    [Pg.1258]    [Pg.94]    [Pg.372]    [Pg.242]    [Pg.184]    [Pg.250]    [Pg.119]    [Pg.12]    [Pg.55]    [Pg.57]    [Pg.68]    [Pg.110]    [Pg.75]    [Pg.88]    [Pg.314]    [Pg.201]    [Pg.193]    [Pg.97]    [Pg.98]    [Pg.448]    [Pg.103]    [Pg.253]    [Pg.3]    [Pg.259]    [Pg.65]    [Pg.111]    [Pg.116]    [Pg.134]    [Pg.506]    [Pg.95]    [Pg.724]   
See also in sourсe #XX -- [ Pg.92 ]




SEARCH



Redundancy

Redundant

© 2024 chempedia.info