Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Rate constants scattering index

Figure 47 shows taken from Equation 20 versus Vj. It shows that S. is quite sensitive to Vp and is therefore a good means to evaluate v, with the numerical values of Fig. 47. It can be estimated that the tensile modulus E of the bulk PMMA is not affected by the very low pressure toluene gas environment during the short duration of the experiment. The optical craze index in PMMA in air without load is known as n = 1.32, which corresponds to v = 0.6. From the optical interferometry, it is known that the craze just before breakage is twice as thick as unloaded, (v, = 0.3) and hence using Lorentz-Lorenz equation its optical index is n = 1.15. From Figs. 46 and 47 it can be concluded that the bulk modulus around the propagating crack is about 4400 MPa, which is a somewhat high value, in view of the strain rates at a propagating crack tip (10 to s" ). Using the scatter displayed in Fig. 46, it can be concluded from Fig. 47 that the fibril volume fraction is constant, v = 0.3, within a scatter band of 0.08, and is therefore not sensitive to the toluene gas. Figure 47 shows taken from Equation 20 versus Vj. It shows that S. is quite sensitive to Vp and is therefore a good means to evaluate v, with the numerical values of Fig. 47. It can be estimated that the tensile modulus E of the bulk PMMA is not affected by the very low pressure toluene gas environment during the short duration of the experiment. The optical craze index in PMMA in air without load is known as n = 1.32, which corresponds to v = 0.6. From the optical interferometry, it is known that the craze just before breakage is twice as thick as unloaded, (v, = 0.3) and hence using Lorentz-Lorenz equation its optical index is n = 1.15. From Figs. 46 and 47 it can be concluded that the bulk modulus around the propagating crack is about 4400 MPa, which is a somewhat high value, in view of the strain rates at a propagating crack tip (10 to s" ). Using the scatter displayed in Fig. 46, it can be concluded from Fig. 47 that the fibril volume fraction is constant, v = 0.3, within a scatter band of 0.08, and is therefore not sensitive to the toluene gas.

See other pages where Rate constants scattering index is mentioned: [Pg.434]    [Pg.3767]    [Pg.184]    [Pg.146]    [Pg.137]    [Pg.86]    [Pg.673]    [Pg.313]    [Pg.164]    [Pg.347]    [Pg.233]    [Pg.32]    [Pg.15]    [Pg.46]    [Pg.80]   
See also in sourсe #XX -- [ Pg.27 ]




SEARCH



Constant index

Rate constants 1056 INDEX

Scattering constants

Scattering indices

Scattering rate

© 2024 chempedia.info