Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pure-component parameters estimation technique

To estimate the pure component parameters, we used the technique of Panagiotopoulos and Kumar (11). The technique provides parameters that exactly reproduce the vapor pressure and liquid density of a subcritical component. Table II presents the pure component parameters that were used. For the supercritical components, the usual acentric factor correlation was utilized. [Pg.127]

For biomaterials that are thermally unstable and decompose before reaching the critical temperature, several estimation techniques are available. We have used the Lydersen group contributions method ( ). Other techniques available for predicting critical properties have been reviewed and evaluated by Spencer and Daubert ( ) and Brunner and Hederer Qfi). It is also possible to determine the EOS parameters from readily measurable data such as vapor pressure, and liquid molar volume instead of critical properties (11). We used the Lydersen method to get pure component parameters because the vapor compositions we obtained were in closer agreement with experiment than those we got from pure component parameters derived by Brunner s method. The critical properties we used for the systems we studied are summarized in Table II. [Pg.101]

This relationship is established by measurement of samples with known amounts of analyte (calibrators). One may distinguish between solutions of pure chemical standards and samples with known amounts of analyte present in the typical matrix that is to be measured (e.g., human serum). The first situation applies typically to a reference measurement procedure, which is not influenced by matrix effects, and the second case corresponds typically to a field method that often is influenced by matrix components and so preferably is calibrated using the relevant matrix. Calibration functions may be linear or curved, and in the case of immunoassays often of a special form (e.g., modeled by the four-parameter logistic curve) This model (logistic in log x) has been used for both radioimmunoassay and enzyme immunoassay techniques and can be written in several forms as shown (Table 14-1). Nonlinear regression analysis is applied to estimate the relationship, or a logit transforma-... [Pg.355]


See other pages where Pure-component parameters estimation technique is mentioned: [Pg.40]    [Pg.16]    [Pg.28]    [Pg.398]    [Pg.436]    [Pg.578]    [Pg.129]    [Pg.379]   
See also in sourсe #XX -- [ Pg.127 , Pg.128 ]




SEARCH



Parameter estimation

Parameter estimation techniques

Pure parameters

Pure-component

Pure-component Parameter Estimation

Pure-component parameters

© 2024 chempedia.info