Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Post-ablation ionization

The large variability in elemental ion yields which is typical of the single-laser LIMS technique, has motivated the development of alternative techniques, that are collectively labeled post-ablation ionization (PAI) techniques. These variants of LIMS are characterized by the use of a second laser to ionize the neutral species removed (ablated) from the sample surface by the primary (ablating) laser. One PAI technique uses a high-power, frequency-quadrupled Nd-YAG laser (A, = 266 nm) to produce elemental ions from the ablated neutrals, through nonresonant multiphoton ionization (NRMPI). Because of the high photon flux available, 100% ionization efflciency can be achieved for most elements, and this reduces the differences in elemental ion yields that are typical of single-laser LIMS. A typical analytical application is discussed below. [Pg.588]

R. W. Odom and B. Schueler. Laser Microprobe Mass Spectrometry Ion and Neutral Analysis, in Lasers and Mass Spectrometry (D. M. Lubman, ed.) Oxford University Press, Oxford, 1990. Presents a useful discussion of LIMS instrumental issues, including the post-ablation ionization technique. Several anal)n ical applications are presented. [Pg.597]

Four of the most commonly used desorption/ionization methods for MSI are secondary ion mass spectrometry (SIMS), desorption electrospray ionization (DESI), matrix-assisted laser desorption/ionization (MALDI), and laser ablation (LA) with post-ionization. Other desorption/ionization approaches such as laser desorption/ionization (LDI) see Chapter 9, (12)), desorption/ionization on silicon (DIOS) (13), electrospray ionization (ESI) (14), and nanostructure-initiator mass spectrometry (NIMS) (15, 16) also have great potential in MSI. Importantly, many mass spectrometers equipped with a MALDI ion source can be used with related ionization processes such as LDI, DIOS, LA, and laser-NIMS. Erequently, a specific ion source arrangement is optimized for a specific mass analyzer for example, MALDI is often interfaced to a time-of-flight (TOF) mass analyzer (described below) although it can also be used with ICR-based instruments. [Pg.25]


See other pages where Post-ablation ionization is mentioned: [Pg.593]    [Pg.27]    [Pg.27]    [Pg.541]    [Pg.34]    [Pg.163]    [Pg.153]    [Pg.240]   
See also in sourсe #XX -- [ Pg.588 ]




SEARCH



Ablate

Ablation

Ablation ionization

Ablator

Ablators

Post-ionization

© 2024 chempedia.info