Portable deposit-corrosion monitors

Portable deposit/corrosion monitors are typically housed in an enclosure of perhaps 30 in. H x 20 in. W x 15 in. D. Components include inlet flow controller, strainer, adjustable electric heater, (outer) see-through glass housing, (inner) heated specimen tube or block, hot/cold temperature readout, corrosion rack, plus thermal overload, low-flow cut-off, and other safety devices. The specimen tubes or blocks are available in different metals (as are the corrosion coupons) and can usually be replaced in a matter of minutes. Unlike test heat exchangers, the cooling water in this type of monitor flows on the shell side of the specimen tube. [Pg.388]


See other pages where Portable deposit-corrosion monitors is mentioned: [Pg.388]    [Pg.388]    [Pg.388]    [Pg.388]    [Pg.807]   
See also in sourсe #XX -- [ Pg.388 ]