Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Plateau Determination

A tritium plateau determination is shown in Figure 6, for the II detector. Using the TMC and ORTEC electronics, the observed results are slightly different than from the Sharp electronics, owing to different logic. The usable range of the tritium counting plateau is ca. 400 volts at 400 cm. Hg pressure. [Pg.189]

The phase boundaries for PDA determined by fluorescence microscopy by Moore etal. are plotted in Fig. 11. Also shown in the figure are the molecular areas A that correspond to the beginning of the LE-LC plateau determined by them from n-A isotherm measurements on pure PDA. Over the full temperature range of the measurements, there is a close coincidence between these areas and the values of obtained in the fluorescence experiments. [Pg.423]

PMMA (conventionai) 393.1 12.21 70.1 390 [82] 37,plateau of the viscoelastic mechanism with compliance above the rubbery plateau determined in the same temperature range as 37,5, but has weaker T-dependence than that of the latter. [Pg.462]

The goal of present investigation is the continuation of the researches on the determination of elemental content in the specimens from Pazyryk graves and the comparison of the elemental interrelations between the all samples. In addition, it was performed the determination of elemental concentrations in hair and nails of contemporary people from Ukok Plateau. [Pg.461]

Since pc 1/2, we observe that Me 2Mg, as commonly observed. Mg is determined from the onset of the rubbery plateau by dynamic mechanical spectroscopy and Me is determined at the onset of the highly entangled zero-shear viscosity law, T) M. This provides a new interpretation of the critical entanglement molecular weight Mg, as the molecular weight at which entanglement percolation occurs while the dynamics changes from Rouse to reptation. It also represents the... [Pg.388]

Fig. 20 shows the density profiles in the reactive and nonreactive parts of the system. The number density in the reactive part is very high (a one-component density at the center of this part is 0.596, so the number density of two components is twice as high). However, the density in the nonreactive part is much lower and equal to 0.404. The application of the test particle methods is therefore easy. There is a well-established density plateau in the nonreactive part consequently, the determination of the bulk density in this part is straightforward and accurate. [Pg.235]

The quality of the packed bed may also be determined by frontal analysis where the sample is applied until it reaches a plateau to give the residence time function and then the solution is momentarily switched to wash to give the washout function. The latter is used to calculate the plate height of the column... [Pg.65]

The enthalpy of the phase conversion can be determined from Eq.(6) by plotting the log of the absorption or desorption plateau pressure, P lnleau, against the reciprocal temperature as indicated in Fig. 2. When the solubility of hydrogen in the metal (or) phase is small, then AHplM AH(, where AH( is essentially the enthalpy of forma... [Pg.211]

Phototubes, multiplier, 56-59, 222 Placement error, 285-287 Planck s constant, 7, 8 Plastics, characterization by absorptiometry, 78, 79 Plateau, characteristic, 60 Platinum, determination by x-ray emission spectrography, 161, 328 L peaks, measured by Bragg, 25, 26, 35 L spectra, 35... [Pg.350]

When the load has reached a critical plateau value, the crack continues to propagate at constant load. Crack propagation can be stopped by removing the load, with the implication that several readings can be made on one test specimen. Crack velocity is determined by the crosshead speed, modulus of the material and specimen dimensions. [Pg.374]


See other pages where Plateau Determination is mentioned: [Pg.57]    [Pg.57]    [Pg.678]    [Pg.998]    [Pg.285]    [Pg.1870]    [Pg.18]    [Pg.57]    [Pg.57]    [Pg.678]    [Pg.998]    [Pg.285]    [Pg.1870]    [Pg.18]    [Pg.422]    [Pg.324]    [Pg.4]    [Pg.68]    [Pg.376]    [Pg.225]    [Pg.606]    [Pg.612]    [Pg.549]    [Pg.219]    [Pg.123]    [Pg.242]    [Pg.409]    [Pg.68]    [Pg.161]    [Pg.96]    [Pg.659]    [Pg.234]    [Pg.269]    [Pg.40]    [Pg.62]    [Pg.115]    [Pg.365]    [Pg.207]    [Pg.101]    [Pg.161]    [Pg.338]    [Pg.238]    [Pg.546]    [Pg.20]    [Pg.20]    [Pg.39]    [Pg.845]    [Pg.334]   
See also in sourсe #XX -- [ Pg.150 , Pg.151 , Pg.158 ]




SEARCH



Determination of the Plateau Modulus

Entanglement molecular weight determination from plateau

Plateau

Plateau modulus determination methods

Storage Plateau modulus, determined

© 2024 chempedia.info