The packed-lantem-ring construction is generally limited to design temperatures below 191°C (375°F) and to me mild services of water, steam, air, lubricating oil, etc. Design gauge pressure does not exceed 2068 kPa (300 Ibfrin for pipe shell exchangers and is limited to 1034 kPa (150 IbEin ) for 610- to 1067-mm- (24- to 42-in-) diameter shells. [Pg.1073]