Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Oxyhydrogen gas

It is important in this experiment to take great care that the gas generator (test tube with nickel electrodes) is removed to a sufficient distance in order to make sure that the oxyhydrogen gas in it does not also explode, as otherwise glass splitters and sulfuric acid will fly across the room The experiment can be repeated several times. [Pg.291]

A process simulation software reports the enthalpy of a saturated liquid stream of 53kg/h of cyclohexane at 45 "C as -2.301 Gcal/h. Estimate this value using the data given in Appendices A and B and compare the results. How much heat per mol of water must be removed to reach a final temperature of T = 1000 K when the oxyhydrogen gas reaction... [Pg.364]

Fig. 2 Historical apparatuses used to study the oxygen evolution reaction (OER) by Johann Wilhelm Ritter (a) [27] and August Wilhelm von Hoffmann (b) [28] as well as a Knallgasvoltameter (oxyhydrogen gas voltameter c) [29], in which the oxygen evolution reaction is employed to measure electric current. In all drawings, the ratio of 2 1 for hydrogen gas to oxygen gas can be seen clearly... Fig. 2 Historical apparatuses used to study the oxygen evolution reaction (OER) by Johann Wilhelm Ritter (a) [27] and August Wilhelm von Hoffmann (b) [28] as well as a Knallgasvoltameter (oxyhydrogen gas voltameter c) [29], in which the oxygen evolution reaction is employed to measure electric current. In all drawings, the ratio of 2 1 for hydrogen gas to oxygen gas can be seen clearly...
Knallgas (2xH2 + O2) oxyhydrogen (gas), detonating gas Knauel polym coil... [Pg.127]

Modern motor vehicle batteries are sealed with a hd which offers a central degassing system (Kamina). A more advanced technology solution is a central degassing outlet sealed by a porous plastic frit, preventing the ignition of the oxyhydrogen gas mixture from outside and at the same time the spilling of acid droplets, in combination with a parallel lid wall construction, the chamber lid (duplex). [Pg.275]

There is an increased danger of explosions in the cooling chamber under the tundish due to possible oxyhydrogen gas reactions. These can lead not only to severe burns, but also to injuries of the tympanic membrane - the latter being possible even in the case of very minimal oxyhydrogen reactions, if an employee is standing very close to the source of the explosion. [Pg.164]


See other pages where Oxyhydrogen gas is mentioned: [Pg.252]    [Pg.59]    [Pg.30]    [Pg.198]    [Pg.285]    [Pg.289]    [Pg.290]    [Pg.291]    [Pg.291]    [Pg.777]    [Pg.402]    [Pg.43]    [Pg.252]    [Pg.55]    [Pg.472]    [Pg.222]    [Pg.222]    [Pg.275]    [Pg.50]   
See also in sourсe #XX -- [ Pg.289 ]




SEARCH



Oxyhydrogen

© 2024 chempedia.info