Other Rotary Agitated Towers

Some performance data are cited for the Kiihni by Ritcey and Ashbrook (1979, p. 102)  [Pg.485]

Most of these types of equipment have at least several hundred installations. The sizing of full scale equipment still requires pilot planting of particular systems. The scaleup procedures require geometrical and hydrodynamic similarities between the pilot and full scale plants. Hydrodynamic similarity implies equalities of [Pg.485]

Sizii of Spray, Packed, or Sieve Tray Towers [Pg.486]

Five theoretical st es are needed for hquid-hquid extraction of a system with these properties  [Pg.486]

Spray towen The flooding velocity is found with Eq. (14.33) 4000(10)  [Pg.486]


Rotating disk contactors or other rotary agitated towers reaiize NETS in the range 0.1-0.5 m. The especially efficient Kuhni with perforated disks of 40% free cross section has NETS 0.2 m and a capacity of 50 hr. [Pg.11]

Rotating disk contactors or other rotary agitated towers realize HETS in the range of 0.1-0.5 m... [Pg.374]