An alternative method of cooling metallurgical offgas is to pass it through sprays of water. Spray cooling avoids investment in waste heat recovery equipment but wastes the heat of the gas. It also generates acidic waste liquid that must be neutralized and treated for solids removal/recycle. [Pg.34]

Fig. 4.5. Dynawave scrubber for removing particulate and soluble impurities from cooled (600 K), partially cleaned furnace offgas (Puricelli et al., 1998 Enviro-chem, 2005). Note the (i) upward sprays in and (ii) the weir atop the downcomer. The sprays clean the gas. The weir continuously overflows water, which wets and cools the downcomer walls. These scrubbers are used for both metallurgical and spent acid regeneration furnace gases. Large scrubber details are downcomer diameter 1 m (Hastelloy G30)... Fig. 4.5. Dynawave scrubber for removing particulate and soluble impurities from cooled (600 K), partially cleaned furnace offgas (Puricelli et al., 1998 Enviro-chem, 2005). Note the (i) upward sprays in and (ii) the weir atop the downcomer. The sprays clean the gas. The weir continuously overflows water, which wets and cools the downcomer walls. These scrubbers are used for both metallurgical and spent acid regeneration furnace gases. Large scrubber details are downcomer diameter 1 m (Hastelloy G30)...