Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Upper partial mean

Uncapacitated Facility Location Problem Upper Partial Mean... [Pg.1]

Table 17. Additional parameters for Upper Partial Mean restriction... Table 17. Additional parameters for Upper Partial Mean restriction...
Thus, this representation of risk is favored and variability, upper partial mean, regret functions, chance constraints, VaR, and the risk premium are disregarded. [Pg.344]

The advantage of the partially fluorinated compounds lies more in their potential to mix with silicone oil. Various groups started activities to diversify the portfolio of silicone oils used as long-term endotamponades to enable a reattachment of a detached retina. Dimethylsiloxanes of different viscosities are well established but their use is limited to the treatment of the upper quadrants of the retina. This is because a 100% filling of the vitreous cavity cannot be achieved, which means that because of their specific gravity, which is 0.97 g/ml, they float on top of the aqueous material present in the vitreous... [Pg.429]

When draining the bottom layer, the speed should be adequate as to not over drain. Over draining means to accidentally drain-off some the upper layer. The opening of the stopcock (either fully or partially open) is determined as the phase boundary of the upper 16... [Pg.16]

The kidneys are retroperitoneal, which means they lie behind the peritoneum, the lining of the abdominal cavity. They are approximately at the vertebral level T12 to L3. The upper parts of the kidneys are partially protected by the 11th and 12th ribs, and each whole kidney is surrounded by two layers of fat (the perirenal and pararenal fat) which help to cushion it. [Pg.365]

Total immersion means standardization with the thermometer immersed to the top of the mercury column, with the remainder of the stem and the upper expansion chamber exposed to the ambient temperature. Partial immersion means standardization with the thermometer immersed to the indicated immersion line etched on the front of the thermometer, with the remainder of the stem exposed to the ambient temperature. If used under any other condition of immersion, an emergent-stem correction is necessary to obtain correct temperature readings. [Pg.831]


See other pages where Upper partial mean is mentioned: [Pg.141]    [Pg.118]    [Pg.141]    [Pg.339]    [Pg.194]    [Pg.179]    [Pg.173]    [Pg.41]    [Pg.289]    [Pg.207]    [Pg.191]    [Pg.84]    [Pg.739]    [Pg.860]    [Pg.90]    [Pg.88]    [Pg.311]    [Pg.74]    [Pg.210]    [Pg.521]    [Pg.625]    [Pg.854]    [Pg.887]    [Pg.1007]    [Pg.1020]    [Pg.151]    [Pg.251]    [Pg.70]    [Pg.108]    [Pg.88]    [Pg.227]    [Pg.80]    [Pg.4]    [Pg.154]    [Pg.314]    [Pg.267]   
See also in sourсe #XX -- [ Pg.141 ]

See also in sourсe #XX -- [ Pg.141 ]




SEARCH



© 2024 chempedia.info