Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Light sources discharge lamps

The condition for observing induced emission is that the population of the first singlet state Si is larger than that of So, which is far from the case at room temperature because of the Boltzmann distribution (see above). An inversion of population (i.e. NSi > Nso) is thus required. For a four-level system inversion can be achieved using optical pumping by an intense light source (flash lamps or lasers) dye lasers work in this way. Alternatively, electrical discharge in a gas (gas lasers, copper vapor lasers) can be used. [Pg.40]

Disilene and its isomer silylsilylene were neither available by standard vacuum flash pyrolysis of precursors 59-63, nor by the more elaborate method of pulsed flash pyrolysis of 60-63, a pulsed discharge in mixtures of argon and mono- and disilane74 or by the matrix photolysis of educts 59-66 using various light sources (Hg lamps, excimer laser)69,70,72, the microwave discharge in disilane 66 or the cocondensation of silicon atoms with SiFLt. [Pg.1156]

The top and the bottom x-ray detector each contain a multiplier phototube coated with phosphor. This tube compares the intensity of the x-ray beam entering the detector with that of the light from the reference standard, a discharge lamp. The reference beam is part of a circuit that maintains the x-ray source at constant intensity. The deviation wedge comes to rest when the intensities of the transmitted x-ray beams stand in a predetermined ratio. At this point, the unbalance in the servo system has been compensated, and the position of the deviation wedge consequently indicates the thickness of the strip. In 1955, this application was made fully automatic that is, the unbalance (or error signal) just mentioned was used to readjust tandem cold reduction mills of the United States Steel Corporation. Automatic control proved significantly more effective than manual control. [Pg.69]

A typical photoionization detector is shown in Figure 3.11. The UV source is a discharge lamp, containing an inert gas or gaal mixture at low pressure, that emits monochromatic light of 1... [Pg.139]

EDL stands for electrodeless discharge lamp. It is an alternative to the hollow cathode lamp as a light source in atomic absorption spectroscopy. [Pg.525]


See other pages where Light sources discharge lamps is mentioned: [Pg.107]    [Pg.243]    [Pg.456]    [Pg.114]    [Pg.753]    [Pg.114]    [Pg.77]    [Pg.1122]    [Pg.1330]    [Pg.2955]    [Pg.2956]    [Pg.120]    [Pg.15]    [Pg.430]    [Pg.418]    [Pg.151]    [Pg.300]    [Pg.431]    [Pg.288]    [Pg.717]    [Pg.762]    [Pg.170]    [Pg.40]    [Pg.293]    [Pg.805]    [Pg.80]    [Pg.86]    [Pg.51]    [Pg.75]    [Pg.25]    [Pg.77]    [Pg.425]    [Pg.134]    [Pg.362]    [Pg.251]    [Pg.258]    [Pg.520]    [Pg.17]    [Pg.392]    [Pg.42]    [Pg.254]   
See also in sourсe #XX -- [ Pg.17 ]

See also in sourсe #XX -- [ Pg.2 , Pg.13 , Pg.15 ]

See also in sourсe #XX -- [ Pg.2 , Pg.13 ]




SEARCH



Discharge lamps

Discharge source

Lamp sources

Lampe

Lamps

Light sources

Light sources lamps

© 2024 chempedia.info