Noble gas sorption experiments were performed on albite melts in an internally heated pressure vessel under 0.1 to 5kbar at 750 to 1200C. The temperature dependence of diffusivities was deduced from Knudsen cell rate-heating and fitted to an Arrhenius equation ... [Pg.276]

Pressure storage tanks should be coirelated using /lb vs. w eight, much the same as other pressure vessels. Materials of construction, of course, would be another variable. Special internals, insulation, and internal heat exchangers should again be separated from the base cost of the tank. The w eight of supports, ladders, and platforms should be estimated and added to the weight of the... [Pg.233]

A vertical cylindrical, and mechanical agitated pressure vessel, equipped with baffles to prevent vortex formation is the most widely used fermenter configuration. The baffles are typically one-tenth of the fermenter diameter in widtli, and are welded to supports tliat extend from the sidewall. A small space between the sidewall and the baffle enables cleaning. Internal heat transfer tube bundles can also be used as baffles. The vessels must withstand a 45 psig internal pressure and full vacuum of -14.7 psig, and comply with the ASME code. [Pg.857]

Internal pressure P (absolute) at failure. (A typical BLEVE is caused by a fire whose heat raises vessel pressure and reduces its wall strength. Safety-valve design allows actual pressure to rise to a value 1.21 times the safety valveopening pressure.)... [Pg.216]

Pi = absolute pressure in vessel at failure Po = ambient pressure outside vessel V = internal volume of vessel 7 = ratio of specific heats... [Pg.225]

Pressure vessels and appurtenances should be constructed of stainless steel or other corrosion-resistant materials. Ideally, these steam generators should receive hot demineralized FW to minimize chemical treatment requirements. Alternatively, where a main boiler plant is installed, 100% steam condensate provides a good source of FW. In practice, it is very difficult to accurately control the correct amount of chemical feed. Chemicals are typically restricted to potable grade, deposit control agents such as polyacrylates, and other materials listed under the Code of Federal Regulations, CFR 21 173.310, or National Sanitary Foundation (NSF International) approval system. These boilers may be electrically heated or gas-fired. [Pg.60]

Failure of Heat Exchanger Tubes If a heat exchanger shell rating is less than the pressure level of the circulating medium and an internal heat exchanging tube ruptures or leaks it will overpressure the vessel. [Pg.137]

Fig. 4.3-21, Pressure vessel with corrosion resis- Fig. 4.3-23. Constructive details of a hair-tent internal bladder [34] pin heat-exchanger, for conditions similiar... Fig. 4.3-21, Pressure vessel with corrosion resis- Fig. 4.3-23. Constructive details of a hair-tent internal bladder [34] pin heat-exchanger, for conditions similiar...
Fig. 4.3-25. Stirred pressure vessel with internally mounted electrical heat pipes [38] ... Fig. 4.3-25. Stirred pressure vessel with internally mounted electrical heat pipes [38] ...
When a pipe or vessel is totally filled with a liquid which can be blocked in, for instance, by closing two isolation valves, the liquid in the pipe or pressure vessel can expand very slowly due to heat gain by the sun or an uncontrolled heating system. This will result in tremendous internal hydraulic forces inside the pipe or pressure vessel, as the liquid is non-compressible and needs to be evacuated. This section of pipe then needs thermal relief (Figure 2.9). [Pg.29]


See other pages where Internally heated pressure vessels is mentioned: [Pg.80]    [Pg.81]    [Pg.82]    [Pg.80]    [Pg.81]    [Pg.82]    [Pg.1958]    [Pg.79]    [Pg.459]    [Pg.85]    [Pg.86]    [Pg.76]    [Pg.67]    [Pg.311]    [Pg.11]    [Pg.331]    [Pg.399]    [Pg.422]    [Pg.422]    [Pg.40]    [Pg.283]    [Pg.115]    [Pg.15]    [Pg.83]    [Pg.66]    [Pg.168]    [Pg.93]    [Pg.611]    [Pg.75]    [Pg.4]    [Pg.67]    [Pg.172]    [Pg.211]    [Pg.218]    [Pg.76]    [Pg.2252]    [Pg.305]    [Pg.992]    [Pg.230]   