The first commercial plasma atomic fluorescence spectrometer was developed by Demers and Allemand. Hollow cathode lamps are used as radiation sources and an inductively coupled plasma torch as an atomizer. Detection limits are reported for more than 30 elements. The linear dynamic range is normally 10 to 10. ... [Pg.211]

Other techniques than CV have been tried for the atomization of mercury from liquid samples. Thus, Lancione and Drew (1985) used a torch of inductively coupled plasma (ICP), but the detection limit was not better than 30 //g/L. It was improved to 0.2 /generating system. However, the best detection limit, 0.04 /ig/L, was achieved when the plasma was shut off, and the instrument was run in the CV-AFS mode. [Pg.426]

Laser-ablation, inductively coupled-plasma mass spectrometry (LA-ICPMS) is an instrumental technique in which a laser-ablahon cell and ophcal microscope supplant the spray chamber/nebulizer apparatus of a standard ICP-MS instrument. Subsamples of questioned material are ablated from a solid sample via laser (often a pulsed Nd-YAG tuned to 266 or 213 nm). Ablated specimens are transported in a stream of Ar to a plasma torch for ionization and mass discrimination as per solution ICP-MS. Only minimal sample prep is required, and few restrictions are placed on the nature of questioned solid samples (Brundle et al. 1992 Vickerman 1998). While laser spot sizes can be reduced to several micrometers, sensitivity is degraded as a result, and usual spatial resolutions are on the order of 10-100 pm. Matrix-matched standards are also necessary for accurate trace-element and isotopic quantitative analyses in LA-ICPMS. Depending on the quality of such primary standards, LA-ICPMS accuracies are typically 1-10%, with limits-of-detection in the parts-per-billion (ppb) range (O Table 62.1). [Pg.2869]


See other pages where Inductively coupled plasma torch detection limits is mentioned: [Pg.31]    [Pg.58]    [Pg.29]    [Pg.34]    [Pg.358]    [Pg.358]    [Pg.89]    [Pg.29]    [Pg.205]    [Pg.204]    [Pg.473]    [Pg.5046]    [Pg.287]    [Pg.121]   
See also in sourсe #XX -- [ Pg.437 , Pg.437 ]




SEARCH



Coupled Plasma

Detectable limit

Detection limits

Detection limits, limitations

Detection-limiting

Induction coupled plasma, detection limits

Induction-coupled plasma

Inductive coupled plasma

Inductive coupling

Inductively couple plasma

Inductively coupled

Inductively detection limits

Plasma torch

© 2024 chempedia.info