Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Immunoaffinity chromatography IAC

Immunoaffinity chromatography (IAC), 6 400—402 12 137, 145 Immunoanalyzers, automated, 14 150 Immunoassay(s), 14 135-159. See also Immunoassay- DNA probe hybrid assays Immunoassay methods Immuno(bio)sensors antibody-antigen reaction, 14 136-138 basic technology in, 14 138-140 chemiluminescent, 14 150-151 classification of, 14 140-153 design of, 14 139-140 enzyme, 14 143-148 fluorescence, 14 148-150 highly specific, 14 153 historical perspective on, 14 136 microarrays and, 14 156—157 microfluidics in, 26 968—969 monoclonal versus polyclonal antibodies in, 14 152-153... [Pg.465]

Affinity Chromatography of Immunoglobulins on immobiiized Antibodies (Immunoaffinity Chromatography, iAC)... [Pg.117]

Key Words Immunoaffinity chromatography IAC isolation purification sample preparation immunoaffinity columns. [Pg.302]

Further examples of separation techniques that exploit the asymmetric distribution of amino acid residues at the surface of folded proteins include metal ion affinity chromatography (HP-IMAC), ligand exchange chromatography (HP-LEC), immunoaffinity chromatography (HP-IAC), hydrophilic chromatography (HP-HILIC), and the various modes of biospecific (HP-BAC), and biomimetic (HP-BMC) chromatography. For example, the... [Pg.119]

Figure 3 Schematic drawing showing the immunoaffinity chromatography/reverse-phase chromatography/atmospheric pressure ionization mass spectrometry experiment. System components are represented as follows P, HPLC pump IAC, immunoaffinity column HPLC, analytical column MS, mass spectrometer with atmospheric pressure ionization interface DS, data system and W, waste. Switching valves are represented as . Figure 3 Schematic drawing showing the immunoaffinity chromatography/reverse-phase chromatography/atmospheric pressure ionization mass spectrometry experiment. System components are represented as follows P, HPLC pump IAC, immunoaffinity column HPLC, analytical column MS, mass spectrometer with atmospheric pressure ionization interface DS, data system and W, waste. Switching valves are represented as .

See other pages where Immunoaffinity chromatography IAC is mentioned: [Pg.117]    [Pg.141]    [Pg.141]    [Pg.830]    [Pg.657]    [Pg.117]    [Pg.141]    [Pg.141]    [Pg.830]    [Pg.657]    [Pg.119]    [Pg.180]    [Pg.200]    [Pg.168]    [Pg.171]    [Pg.265]    [Pg.45]   
See also in sourсe #XX -- [ Pg.33 ]




SEARCH



Chromatography immunoaffinity

IAC

Immunoaffinity

© 2024 chempedia.info